06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
71
Measure
Check if the spelling of the graphics file is the same both in the #YG
command and on the compactflash card.
8852 Graphic
header
Status
A graphics file declared by a Easy Plug #YG command should be
proceeded. The file header doesn´t match the file.
Measure
The graphics file is possibly faulty. Check the file and replace it if
necessary.
8853 Graphic
palette
Status
A graphics file declared by a Easy Plug #YG command should be
proceeded. Error reading the graphics palette.
Measure
The graphics file is possibly faulty. Check the file and replace it if
necessary.
8854 Graphic
read
Status
A graphics file declared by a Easy Plug #YG command should be
proceeded. Error reading the file.
Measure
The graphics file is possibly faulty. Check the file and replace it if
necessary.
8856
Free store size
Status
By setting parameter
SYSTEM PARAMETER > Free store size
, a part of the
memory is reserved, which the printer firmware can use if necessary
(dynamic memory allocation). If this memory area is dimensioned too small,
the printer firmware can not work and this error message shows up. One
cause may for example be, that data are supposed to be loaded, whose
size exceeds the reserved memory (e. g. graphics).
Measure
Enlarging the reserved memory partition, that is increasing the value of
SYSTEM PARAMETER > Free store size
.
8857
Wrong mem config
Wrong memory configuration
Status
Too much memory requested by parameters. The following parameters
request more or less memory:
•
SYSTEM PARAMETER > Font downl. area
•
SYSTEM PARAMETER > Ram disk size
•
SYSTEM PARAMETER > Free store size
The fault occurs, if the sum of requested memory space exceeds the
amount of available memory.
After error confirmation, the relevant parameters are set back to their
default values. Furthermore, a restart is triggered.
Measure
Change the settings of the relevant parameters.