Chapter 5: Switching Commands
547
lldp timers
Use this command to set the timing parameters for local data transmission on
ports enabled for LLDP. The
interval-seconds
determines the number of
seconds to wait between transmitting local data LLDPDUs. The range is 1-32768
seconds. The
hold-value
is the multiplier on the transmit interval that sets the
TTL in local data LLDPDUs. The multiplier range is 2-10. The
reinit-
seconds
is the delay before reinitialization, and the range is 1-0 seconds.
no lldp timers
Use this command to return any or all timing parameters for local data
transmission on ports enabled for LLDP to the default values.
lldp transmit-tlv
Use this command to specify which optional type length values (TLVs) in the
802.1AB basic management set are transmitted in the LLDPDUs from an
interface or range of interfaces. Use
sys-name
to transmit the system name
TLV. To configure the system name, see “
” on page 89. Use
sys-
desc
to transmit the system description TLV. Use
sys-cap
to transmit the
system capabilities TLV. Use
port-desc
to transmit the port description TLV.
To configure the port description, see “
.
Mode
Interface Config
Default
◆
interval—30 seconds
◆
hold—4
◆
reinit—2 seconds
Format
lldp timers
[interval
interval-seconds
] [hold
hold-
value
] [reinit
reinit-seconds
]
Mode
Global Config
Format
no lldp timers [interval] [hold] [reinit]
Mode
Global Config
Default
no optional TLVs are included
Format
lldp transmit-tlv [sys-desc] [sys-name] [sys-cap]
[port-desc]
Mode
Interface Config