Chapter 4: Utility Commands
167
show fiber-ports
optical-transceiver
This command displays the diagnostics information of the SFP like Temp,
Voltage, Current, Input Power, Output Power, Tx Fault, and LOS. The values are
derived from the SFP's A2 (Diagnostics) table using the I
2
C interface.
The following information shows an example of the command output:
(CN1610) #show fiber-ports optical-transceiver all
Output Input
Port Temp Voltage Current Power Power TX LOS
[C] [Volt] [mA] [dBm] [dBm] Fault
-------- ---- ------- ------- ------- ------- ----- ---
0/49 39.3 3.256 5.0 -2.234 -2.465 No No
0/50 33.9 3.260 5.3 -2.374 -40.000 No Yes
0/51 32.2 3.256 5.6 -2.300 -2.897 No No
Time Since Counters
Last Cleared
The elapsed time, in days, hours, minutes, and
seconds since the statistics for this LAG were last
cleared.
Parameters
Definition
Format
show fiber-ports optical-transceiver {all | slot/port}
Mode
Privileged EXEC
Field
Description
Temp
Internally measured transceiver temperature.
Voltage
Internally measured supply voltage.
Current
Measured TX bias current.
Output Power
Measured optical output power relative to 1mW.
Input Power
Measured optical power received relative to 1mW.
TX Fault
Transmitter fault.
LOS
Loss of signal.