![NetApp CN1610 Cli Command Reference Download Page 258](http://html.mh-extra.com/html/netapp/cn1610/cn1610_cli-command-reference_1669922258.webp)
Chapter 4: Utility Commands
255
Src_IP: 11.1.1.1 Dest_IP: 225.0.0.5 Type: Membership_Query Group:
225.0.0.5
The following parameters are displayed in the trace message:
no debug
igmpsnooping
receive
This command disables tracing of received IGMP Snooping packets.
Parameter
Definition
RX
A packet received by the device.
Intf
The interface that the packet went out on. Format
used is unit/slot/port (internal interface number).
Unit is always shown as 1 for interfaces.
Src_Mac
Source MAC address of the packet.
Dest_Mac
Destination multicast MAC address of the packet.
Src_IP
The source IP address in the ip header in the packet.
Dest_IP
The destination multicast ip address in the packet.
Type
The type of IGMP packet. Type can be one of the
following:
◆
Membership_Query
– IGMP Membership
Query
◆
V1_Membership_Report
– IGMP Version 1
Membership Report
◆
V2_Membership_Report
– IGMP Version 2
Membership Report
◆
V3_Membership_Report
– IGMP Version 3
Membership Report
◆
V2_Leave_Group
– IGMP Version 2 Leave
Group
Group
Multicast group address in the IGMP header.
Format
no debug igmpsnooping receive
Mode
Privileged EXEC
Summary of Contents for CN1610
Page 3: ......
Page 31: ...28 Accessing the CLI ...
Page 309: ...306 Remote Monitoring Commands ...
Page 473: ...470 Port Mirroring Commands 100 ...
Page 487: ...484 DHCP L2 Relay Agent Commands Mode Privileged EXEC ...