![NetApp CN1610 Cli Command Reference Download Page 278](http://html.mh-extra.com/html/netapp/cn1610/cn1610_cli-command-reference_1669922278.webp)
Chapter 4: Utility Commands
275
sFlow Commands
sFlow is the standard for monitoring high-speed switched and routed networks.
sFlow technology is built into network equipment and gives complete visibility
into network activity, enabling effective management and control of network
resources.
sflow receiver
Use this command to configure the sFlow collector parameters (owner string,
receiver timeout, max datagram size, IP address, and port).
Format
sflow receiver
rcvr_idx
{owner
owner-string
timeout
rcvr_timeout
| max datagram
size
| ip
ip
| port
port
}
Mode
Global Config
Parameter
Description
Receiver Owner
The identity string for the receiver, the entity making
use of this sFlowRcvrTable entry. The range is 127
characters. The default is a null string. The empty
string indicates that the entry is currently unclaimed
and the receiver configuration is reset to the default
values. An entity wishing to claim an
sFlowRcvrTable entry must ensure that the entry is
unclaimed before trying to claim it. The entry is
claimed by setting the owner string to a non-null
value. The entry must be claimed before assigning a
receiver to a sampler or poller.
Receiver Timeout
The time, in seconds, remaining before the sampler
or poller is released and stops sending samples to
receiver. A management entity wanting to maintain
control of the sampler is responsible for setting a
new value before the old one expires. The allowed
range is 0-2147483647 seconds. The default is zero
(0).
No Timeout
The configured entry will be in the config until you
explicitly removes the entry.
Summary of Contents for CN1610
Page 3: ......
Page 31: ...28 Accessing the CLI ...
Page 309: ...306 Remote Monitoring Commands ...
Page 473: ...470 Port Mirroring Commands 100 ...
Page 487: ...484 DHCP L2 Relay Agent Commands Mode Privileged EXEC ...
Page 607: ...604 IPv6 Management Commands ...