![NetApp CN1610 Cli Command Reference Download Page 234](http://html.mh-extra.com/html/netapp/cn1610/cn1610_cli-command-reference_1669922234.webp)
Chapter 4: Utility Commands
231
Time Zone Commands
Use the Time Zone commands to configure system time and date, Time Zone and
Summer Time (that is, Daylight Saving Time). Summer time can be recurring or
non-recurring.
clock set
This command sets the system time and date.
The following shows examples of the command.
(CN1610) (Config)# clock set 03:17:00
(CN1610) (Config)# clock set 11/01/2011
clock summer-time
date
Use the clock summer-time date command to set the summer-time offset to
Coordinated Universal Time (UTC). If the optional parameters are not specified,
they are read as either
0
or
\0
, as appropriate.
Format
clock set
hh:mm:ss
clock set
mm/dd/yyyy
Mode
Global Config
Parameter
Description
hh:mm:ss
Enter the current system time in 24-hour format in
hours, minutes, and seconds. The range is hours: 0 to
23, minutes: 0 to 59, seconds: 0 to 59.
mm/dd/yyyy
Enter the current system date the format month, day,
year. The range for month is 1 to 12. The range for
the day of the month is 1 to 31. The range for year is
2010 to 2079.
Format
clock summer-time date {
date month
year hh:mm
date
month
year
hh:mm
}[offset
offset
] [zone
acronym
]
Mode
Global Config
Summary of Contents for CN1610
Page 3: ......
Page 31: ...28 Accessing the CLI ...
Page 309: ...306 Remote Monitoring Commands ...
Page 473: ...470 Port Mirroring Commands 100 ...
Page 487: ...484 DHCP L2 Relay Agent Commands Mode Privileged EXEC ...
Page 607: ...604 IPv6 Management Commands ...