NAVIS NavDP 4000. Operation Manual
Figure 2.17: Control Panel Controls, Buttons and Indicators (MCP and PCP)
Disconnected panel
In case the panel has no signal from the system the status is “Disconnected”. In this state all push buttons have white
backlights, but the color of the indicators corresponds their status (see the sections below).
2.5.1
Power
Indicates if the system is powered.
2.5.2
OPERATION
Indicates if the system is active. Highlighting means that the vessel is under the system control.
2.5.3
TAKE/GIVE
The TAKE/GIVE button is used for transferring control between:
– DP A and DP B systems (for DP-2 systems) ;
– control panels of the control system( if two or more control panels are in use).
The active panel button is green highlighted.
The system operates in one of the control transferring modes:
– Take
– GiveTake
The mode settings are performed when the system is configured and not allowed to change using the software GUI.
Take Mode
Control can be taken to any control panel holding the
TAKE/GIVE
button.
33