Parameter Description
Meaning
% of the Hold Area Radius. The radius of the area where the
vessel stops.
Mode
Hold Area
Values
0–100 %
Editing/ Viewing
Hold Area
COR Point Edit
The page contains a vessel layout view and the COR list.
Arrows Up and Down
Meaning
Navigation between the points (table rows)
Mode
Service controls
Values
–
Editing/ Viewing
COR
EDIT
Meaning
Calls the coordinate settings dialog
Mode
Service control
Values
–
Editing/ Viewing
COR
Auto Pilot parameters
RATE OF TURN
Meaning
The ceiling value of the turning angle
Mode
AP
Values
5–80
∘
/min
Editing/ Viewing
AP
OFF-HEADING LIMIT
Meaning
The ceiling value of the off-heading. In case of the value
surpassing an alarm is generated.
Mode
AP
Values
2, 3, 10, 15
∘
Editing/ Viewing
AP
HEADING GAIN
Meaning
The heading gain settings
Mode
AP
Values
1–10
Editing/ Viewing
AP
SPEED GAIN
Meaning
The speed gain settings
Mode
AP
Values
1–10
Editing/ Viewing
AP
RUDDER LIMIT
Doc. 000.JDP-10000-OME, rev.3.3.13/“2102.$–17A-Advanced”