NAVIS NavDP 4000. Operation Manual
M
— Magnetic
x.x
— Knots (speed of vessel relative to the water)
N
— Knots
x.x
— Kilometers (speed of vessel relative to the water)
K
— Kilometres
hh
— Checksum
Example
$VDVHW,,,,,16.5,N,,*09
Tension Sensor
The message format:
$PPDMT,xxx.x,xxx.x,xxxx.x,A*hh
where:
PP
— Talker identifier
xxx.x
— Velocity in meters, min negative for pay out and positive pay in (reserved field)
xxx.x
— Force in KN
xxxx.x
— Wire on drum meters (reserved field)
A
— Status (A/V — valid/invalid)
hh
— Checksum
Example
$PPDMT,,98.00,,A*33
Figure D.1: True and relative (apparent) wind
283