12 - 20
Chapter 12 Expansion Control
POINT
(1) Automatic switching is valid only when the control mode is switched from the
position control mode to the continuous operation to torque control mode.
When the mode is switched from speed control mode to continuous operation
to torque control mode or from continuous operation to torque control mode to
other control modes, even if the automatic switching is set, the state is not
waiting for the completion of condition, and control mode switching is executed
immediately.
(2) When the mode switching request is executed after setting the switching
condition, the state of waiting for the completion of control mode switching
condition continues until the setting condition is satisfied. Therefore, if the
positioning by automatic switching is interrupted, unexpected control mode
switching may be executed in other positioning operations. Waiting for the
completion of control mode switching condition can be cancelled by setting
"Other than 1: Not request" in "
Cd.138
Control mode switching request
" or by
turning the axis stop signal ON. When an error occurs, waiting for the
completion of control mode switching condition is also cancelled. (In both
cases, "0" is stored in "
Cd.138
Control mode switching request
".)
(3) In the state of waiting for the completion of control mode switching condition, if
the current values are updated by the current value changing, the fixed-feed
control or the speed control (when "2: Clear current feed value to zero" is set in
"
Pr.21
Current feed value during speed control
"), an auto-shift judgment is
executed based on the updated current value. Therefore, depending on the
setting condition, the mode may be switched to the continuous operation to
torque control mode immediately after the positioning starts. To avoid this
switching, set "1: Switching request" in "
Cd.138
Control mode switching request
".
Summary of Contents for MELSEC-L Series
Page 2: ......
Page 30: ...MEMO ...
Page 70: ...2 10 Chapter 2 System Configuration MEMO ...
Page 83: ...3 13 Chapter 3 Specifications and Functions MEMO ...
Page 103: ...3 33 Chapter 3 Specifications and Functions MEMO ...
Page 107: ...3 37 Chapter 3 Specifications and Functions MEMO ...
Page 111: ...3 41 Chapter 3 Specifications and Functions MEMO ...
Page 115: ...3 45 Chapter 3 Specifications and Functions MEMO ...
Page 140: ...4 22 Chapter 4 Installation Wiring and Maintenance of the Product MEMO ...
Page 253: ...5 113 Chapter 5 Data Used for Positioning Control MEMO ...
Page 342: ...5 202 Chapter 5 Data Used for Positioning Control MEMO ...
Page 438: ...7 20 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 440: ...MEMO ...
Page 485: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 594: ...9 134 Chapter 9 Major Positioning Control MEMO ...
Page 624: ...10 30 Chapter 10 High Level Positioning Control MEMO ...
Page 656: ...11 32 Chapter 11 Manual Control MEMO ...
Page 690: ...12 34 Chapter 12 Expansion Control MEMO ...
Page 798: ...13 108 Chapter 13 Control Sub Functions MEMO ...
Page 866: ...14 68 Chapter 14 Common Functions MEMO ...
Page 884: ...15 18 Chapter 15 Dedicated Instructions MEMO ...
Page 899: ...16 15 Chapter 16 Troubleshooting MEMO ...
Page 1036: ...Appendix 88 Appendices MEMO ...
Page 1039: ......