13 - 85
Chapter 13 Control Sub Functions
13.7.5 Command in-position function
The "command in-position function" checks the remaining distance to the stop position
during the automatic deceleration of positioning control, and sets "1". This flag is called
the "command in-position flag". The command in-position flag is used as a front-
loading signal indicating beforehand the completion of the position control.
The details shown below explain about the "command in-position function".
[1] Control details
[2] Precautions during control
[3] Setting the command in-position function
[4] Confirming the command in-position flag
[1] Control details
The following shows control details of the command in-position function.
(1) When the remaining distance to the stop position during the automatic
deceleration of positioning control becomes equal to or less than the value
set in "
Pr.16
Command in-position width
", "1" is stored in the command in-
position flag (
Md.31
Status
: b2).
(Command in-position width check)
Remaining distance
"
Pr.16
Command in-position width
" setting value
Positioning
V
t
ON
OFF
Command in-position flag
( Md.31 Status : b2)
Command in-position
width setting value
Fig. 13.41 Command in-position operation
(2) A command in-position width check is carried out every operation cycle.
Summary of Contents for MELSEC-L Series
Page 2: ......
Page 30: ...MEMO ...
Page 70: ...2 10 Chapter 2 System Configuration MEMO ...
Page 83: ...3 13 Chapter 3 Specifications and Functions MEMO ...
Page 103: ...3 33 Chapter 3 Specifications and Functions MEMO ...
Page 107: ...3 37 Chapter 3 Specifications and Functions MEMO ...
Page 111: ...3 41 Chapter 3 Specifications and Functions MEMO ...
Page 115: ...3 45 Chapter 3 Specifications and Functions MEMO ...
Page 140: ...4 22 Chapter 4 Installation Wiring and Maintenance of the Product MEMO ...
Page 253: ...5 113 Chapter 5 Data Used for Positioning Control MEMO ...
Page 342: ...5 202 Chapter 5 Data Used for Positioning Control MEMO ...
Page 438: ...7 20 Chapter 7 Memory Configuration and Data Process MEMO ...
Page 440: ...MEMO ...
Page 485: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Page 594: ...9 134 Chapter 9 Major Positioning Control MEMO ...
Page 624: ...10 30 Chapter 10 High Level Positioning Control MEMO ...
Page 656: ...11 32 Chapter 11 Manual Control MEMO ...
Page 690: ...12 34 Chapter 12 Expansion Control MEMO ...
Page 798: ...13 108 Chapter 13 Control Sub Functions MEMO ...
Page 866: ...14 68 Chapter 14 Common Functions MEMO ...
Page 884: ...15 18 Chapter 15 Dedicated Instructions MEMO ...
Page 899: ...16 15 Chapter 16 Troubleshooting MEMO ...
Page 1036: ...Appendix 88 Appendices MEMO ...
Page 1039: ......