7. COMPUTER LINK CONNECTION
7.5 PLC Side Setting
(e) A2CCPUC24, A2CCPUC24-PRF
• Transmission speed setting (SW11 to SW13)
Set the transmission speed (SW11 to SW13) as
follows.
The transmission speed setting must be consistent
with that of the GOT side.
*1
Only transmission speeds available on the GOT side are
shown.
(3) Station number setting switch
*2
The station number setting switch in the figure is for the
A1SJ71UC24-R4.
POINT
POINT
POINT
When the switch setting has been changed
Turn the PLC CPU OFF then ON again, or reset the
PLC CPU.
POINT
POINT
POINT
When connecting the GT14, GT12, GT11, GT10 and
the computer link unit
When the GT14, GT12, GT11, GT10 and the computer
link unit are connected via RS-232C, set the buffer
memory in the computer link unit using the sequence
program so that CD signals are not checked.
Examples of the CPU units equipped with built-in
computer link are explained below also.
(1) In the case of A computer link
Refer to the program example below in which the
I/O signals of the computer link unit are 80 to 9F
(H).
(2) In the case of CPU equipped with built-in
computer link
(a) A1SCPUC24-R2
(b) A2CCPUC2
Transmission
specifications
switch
Setting
switch
Description
Set
value
SW11
Transmission speed
setting
(Consistent
with the GOT
side
specifications)
See
descriptio
ns below.
SW12
SW13
SW14
Data bit setting
8bits
ON
SW15
Parity bit setting
Set
ON
SW16
Even/odd parity
setting
Odd
OFF
SW17
Stop bit setting
1bit
OFF
SW18
Sum check setting
Set
ON
SW19
Main channel setting
RS-232
OFF
SW20
Write during RUN
enabled/
disabled setting
Enabled
ON
Setting switch
Transmission speed
*1
4800bps
9600bps
19200bps
SW11
OFF
ON
OFF
SW12
OFF
OFF
ON
SW13
ON
ON
ON
Station number switch
*2
Description
Set value
Set the station number of the
computer link module to
which an access is made
from the GOT.
0
ON
SW
11
12
13
14
15
16
17
18
19
20
ON
OFF
2
1
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
10
1
STATION NO.
X87
TO
Write to buffer memory
10B(H):CD terminal will be checked
K1:CD terminal will not be checked
Computer link unit
connection point
H8
H10B
K1
K1
P
X0E7
TO
Write to buffer memory
10B(H):CD terminal will be checked
K1:CD terminal will be checked
Fixed values
Computer link unit connection point
(Fixed values)
H0E
H10B
K1
K1
P
X1E7
TO
Write to buffer memory
10B(H):CD terminal will be checked
K1:CD terminal will not be checked
Fixed values
Computer link unit connection point
(Fixed values)
K61
H10B
K1
K1
P
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......