23. FA TRANSPARENT FUNCTION
23.2 Compatible Software
23 - 11
17
ROBOT
CONT
ROLLER
CONN
E
C
TION
18
C
NC CONNECTION
19
ENER
GY M
EAS
URIN
G
UNIT/EL
EC
TRIC M
U
LT
I-
ME
ASUR
ING IN
STRU
MEN
T
CO
NNE
CTION
20
GOT
MUL
T
I-DROP
CONNECTION
21
MUL
TI
PL
E-GT1
4, G
T12,
GT
11
, GT
10
CO
NNECTIO
N FUNCTION
22
MUL
T
I-CHA
N
N
E
L
FUNCT
ION
23
F
A
TRANS
P
ARENT
FUNCTION
(4) When connecting the GOT and PLC in Ethernet communication
The following shows the software and the accessible PLC CPUs.
*1
Only QCPU can be connected.To connect to QnA/ACPU, connect via QCPU.
*2
GX Developer Version 8.78G or later is required to use the FA transparent function.
*3
MELSOFT Navigator Version 1.04E or later is required to use the FA transparent function.
*4
GX Works2 Version 1.10L or later is required to use the FA transparent function.
*5
MT Works2 Version 1.08J or later is required to use the FA transparent function.
*6
NC Configurator Version A1 or later is required to use the FA transparent function.
*7
GX Developer Version 8.88S or later is required to use the FA transparent function.
*8
GX Works2 Version 1.11M or later is required to use the FA transparent function.
*9
MT Works2 Version 1.12N or later is required to connect with Q17nDCPU-S1.
*10
MELSOFT Navigator Version 1.07H or later is required to use the FA transparent function.
*11
MX Component Version 4.03D or later is required to use the FA transparent function.
*12
Use MX Component Version 3.14Q or later for MX Sheet.
*13
GX Works2 Version 1.34L or later is required to execute the FA transparent function with using CC-Link IE Field Network Ethernet
adapter (NZ2GF-ETB).
C controller module (Q Series) does not support CC-Link IE Field Network.
*14
CPU Module Logging Configuration Tool Version 1.04E or later is required to use the FA transparent function.
*15
RT ToolBox2 Version 1.7 or later is required to use the FA transparent function.
*16
MR Configurator2 Version 1.09K or later is required to use the FA transparent function.
*17
A motion controller is required between the GOT and PLC in Ethernet connection.
*18
Setting/Monitoring tool for C Controller module Version 4.00A or later is required to use the FA transparent function.
*19
GX Works2 Version 1.98C or later is required to use the FA transparent function.
*20
MT Works2 Version 1.100E or later is required to use the FA transparent function.
*21
MX Component Version 4.06G or later is required to use the FA transparent function.
*22
Use MX Component Version 4.06G or later for MX Sheet.
*23
GX Works3 Version 1.005F or later is required to use the FA transparent function.
*24
MX Component Version 4.11M or later is required to use the FA transparent function.
*25
MX Sheet, please use the MX Component (Version 4.11M or later).
PLC CPU
Software
RCPU
GX Works3, MX Component
*21
, MX Sheet
*22
Motion controller CPU (MELSEC iQ-R Series)
MT Works2
*20
, MX Component
*21
, MX Sheet
*22
C Controller module (MELSEC iQ-R Series)
CW Configurator
FX5U, FX5UC
GX Works3
*23
,
MX Component
*24
,
MX Sheet
*25
QCPU (Q mode)
*1
, C Controller module (Q Series)
MELSOFT Navigator
*3
GX Developer
*2
GX Works2
*4*13
MX Component
*11
,
MX Sheet
*12
Setting/Monitoring tool for C Controller module
*18
LCPU
MELSOFT Navigator
*10
GX Developer
*7
GX Works2
*8
GX LogViewer
MX Component
*11
,
MX Sheet
*12
,
CPU Module Logging Configuration Tool
*14
FXCPU
GX Works2
*19
QCPU (A mode), QnA/ACPU
*1
GX Developer
*2
MX Component
*11
,
MX Sheet
*12
Motion controller CPU (Q Series)
MELSOFT Navigator
*3
MT Works2
*5*9
CNC CPU(Q173NCCPU)
NC Configurator
*6
Robot controller (CRnQ-700, CRnD-700)
RT ToolBox2
*15
MELSERVO(MR-J3-B)
*17
MR Configurator2
MELSERVO(MR-J4-B)
*17
MR Configurator2
*16
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......