7. COMPUTER LINK CONNECTION
7.5 PLC Side Setting
7 - 27
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
D
E
VICE RA
NGE
T
H
A
T
CAN
B
E
SET
3
ACCESS
RA
N
G
E
F
O
R MONIT
O
R
ING
4
HOW T
O
MONIT
O
R
REDUNT
ANT
SYS
TEM
5
BUS CONNECTION
6
DIR
E
CT
CONNECTION T
O
CPU
7
COMP
UT
E
R
L
INK
CONNE
C
T
ION
8
E
T
HE
RN
E
T
CONN
E
C
T
ION
POINT
POINT
POINT
When connecting a GOT to CH2
Set the CH1 side mode switch to any other than "0"
(interlocked operation).
(2) Transmission specifications setting switch
*1
The following shows the layout of switches in the case of the
following hardware versions for the module.
Switch settings and switch ON/OFF directions are the same.
(a) Transmission speed setting (SW09 to SW12)
Set the transmission speed (SW09 to SW12) as
follows.
The transmission speed setting must be consistent
with that of the GOT side.
*1
Only transmission speeds available on the GOT side are
shown.
*2
When the software version of AJ71QC24 (-R2/R4) and
A1SJ71QC24 (-R2) is "L" or earlier, and when 2 devices are
connected to the two interfaces individually, make the setting
so that the total transmission speed of the two interfaces is
within 19200bps.
When the total transmission speed of the two interfaces is
within 19200bps, a controller other than GOT can be
connected to the computer link module.
When only one device is connected to either of the
interfaces, a maximum transmission speed of 19200bps can
be set to the one where the device is connected.In this
instance, set SW09 to SW12 to "OFF" on the other side.
*3
When 3 devices are connected to the two interfaces
individually in the case of AJ71QC24N(-R2/R4),
A1SJ71QC24N(-R2), and A1SJ71QC24N1(-R2), make the
setting so that the total transmission speed of the two
interfaces is within 115200bps (within 230400bps in the case
of A1SJ71QC24N1(-R2)).
When the total transmission speed of the two interfaces is
within 115200bps (within 230400bps in the case of
A1SJ71QC24N1(-R2)), a controller other than GOT can be
connected to the computer link module.
When only one device is connected to either of the
interfaces, a maximum transmission speed of 115200bps
can be set to the one where the device is connected.In this
instance, set SW09 to SW12 to "OFF" on the other side.
*4
This can be set only in the case of AJ71QC24N (-R2/R4),
A1SJ71QC24N (-R2) or A1SJ71QC24N1 (-R2).
(3) Station number switch (for both CH1 and CH2)
*5
The station number switch in the figure is for the AJ71QC24
(N) (-R2/R4).
POINT
POINT
POINT
When the switch setting has been changed
Turn the PLC CPU OFF then ON again, or reset the
PLC CPU.
Transmission
specifications setting
switch
Setting
switch
Description
Set
value
AJ71QC24(N)
(-R2/R4)
A1SJ71QC24(N)
(N1)(-R2)
*1
SW01
Operation
setting
Independent
operation
OFF
SW02
Data bit
setting
8bits
ON
SW03
Parity bit
enable/disable
setting
Enable
ON
SW04
Even/odd parity
setting
Odd
OFF
SW05
Stop bit setting
1bit
OFF
SW06
Sum check
enable/disable
setting
Enable
ON
SW07
Write during
RUN enable/
disable setting
Enable
ON
SW08
Setting change
enable/disable
Disable
(prohibit)
OFF
SW09
to
SW12
Transmission
speed setting
(Consistent
with the GOT
side
specifications)
See (a)
SW13
to
SW15
―
The switch is
located on
the left side
of the
module.
(only on
AJ71QC24 (-
R2/R4))
All OFF
Target unit
Hardware version
A1SJ71QC24
Version E hardware or earlier
A1SJ71QC24-R2
Version D hardware or earlier
A1SJ71QC24N, A1SJ71QC24N-R2
Version A hardware
MODE
CH2
CH1
SW
01
02
03
04
05
06
07
08
09
10
11
12
ON
ON
ON
2
1
4
3
6
5
8
7
10
9
12
11
SW
1
8
2
3
4
5
6
7
9
10
11
12
SW
CH1/2
ON
Setting
Switch
Transmission speed
*1*2*3
4800
bps
9600
bps
19200
bps
38400
bps
*4
57600
bps
*4
115200
bps
*4
SW09
OFF
ON
OFF
ON
OFF
ON
SW10
OFF
OFF
ON
ON
ON
ON
SW11
ON
ON
ON
ON
OFF
OFF
SW12
OFF
OFF
OFF
OFF
ON
ON
Station number switch
*5
Contents
Set
value
Set the station number of the
serial communication module
to which an access is made
from the GOT.
0
1
STATION
No.
10
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......