22 - 30
22. MULTI-CHANNEL FUNCTION
22.3 GOT Side Settings
(2) Combinations of units that affect the number of available channels
The following are examples of unit combinations that affect the number of available channels.
POINT
POINT
POINT
Installing a unit on another unit (Checking the unit installation position)
For details on the precautions for installing units on another unit, refer to the following.
1.3.7 Installing a unit on another unit (Checking the unit installation position)
For the installation method of each unit, refer to the User's Manual for the communication unit and option unit you
are using.
For the method for installing a unit on another unit, refer to the following.
User's Manual of GOT used.
Example 1) To add the printer output (when using a PictBridge compatible printer) and the Ethernet download in
a system using the bus connection (1 channel), serial connection (3 channels), and the barcode
function
(a) For GT16
Mount the printer unit at the third stage, and use the Ethernet interface built in the GOT. This enables both
the printer output of the report function and the Ethernet download.
(b) For GT15
Because units can be mounted up to the third stage for GT15, the printer output of the report function and
the Ethernet download cannot be used together.
Serial communication
unit
Serial communication
unit
Serial communication
unit
Printer unit
Barcode reader
Bus connection unit
Ethernet communication
unit
Printer unit
Barcode reader
Bus connection unit
Serial communication
unit
Serial communication
unit
Serial communication
unit
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......