1 - 20
1. PREPARATORY PROCEDURES FOR MONITORING
1.3 Option Devices for the Respective Connection
1.3.7
Installing a unit on another unit (Checking the unit installation position)
This section describes the precautions for installing units on another unit.
For the installation method of each unit, refer to the User's Manual for the communication unit and option unit you are
using.
For the method for installing a unit on another unit, refer to the following.
User's Manual of GOT used.
Calculating consumed current
For using multiple extension units, a bar code reader, or a RFID controller, the total current for the extension units,
bar code reader, or RFID controller must be within the current that the GOT can supply.
For the current that the GOT can supply and the current for the extension units, bar code reader, or RFID controller,
refer to the following tables. Make sure that the total of consumed current is within the capacity of the GOT.
(1) Current supply capacity of the GOT
(2) Current consumed by an extension unit/barcode reader/RFID controller
*1
Value used for calculating the current consumption of the multi-channel function.
For the specifications of the unit, refer to the manual included with the unit.
*2
When the GOT supplies power to a barcode reader or a RFID controller from the standard interface, add their consumed current.
(Maximum value is less than 0.3 A)
GOT type
Current supply
capacity
(A)
GOT type
Current supply
capacity
(A)
GT1695M-X
2.4
GT1595-X
2.13
GT1685M-S
2.4
GT1585V-S
1.74
GT1675M-S
2.4
GT1585-S
1.74
GT1675M-V
2.4
GT1575V-S
2.2
GT1675-VN,
GT1672-VN
2.4
GT1575-S
2.2
GT1665M-S
2.4
GT1575-V,
GT1572-VN
2.2
GT1665M-V
2.4
GT1565-V,
GT1562-VN
2.2
GT1662-VN
2.4
GT1555-V
1.3
GT1655-V
1.3
GT1555-Q,
GT1550-Q
1.3
Module type
Consumed
current
(A)
Module type
Consumed
current
(A)
GT15-QBUS,
GT15-QBUS,
GT15-75QBUSL,
GT15-75QBUS2L
0.275
*1
GT16M-R2
0
*1
GT15-ABUS,
GT15-ABUS2,
GT15-75ABUSL,
GT15-75ABUS2L
0.12
GT15V-75R1
0.2
*1
GT15-RS2-9P
0.29
GT16M-V4R1
0.12
*1
GT15-RS4-9S
0.33
GT15V-75V4R1
0.2
*1
GT15-RS4-TE
0.3
GT16M-ROUT
0.11
*1
GT15-RS2T4-9P
0.098
GT15V-75ROUT
0.11
GT15-J71E71-100
0.224
GT16M-MMR
0.27
*1
GT15-J71GP23-SX
1.07
GT15-CFCD
0.07
GT15-J71LP23-25
0.56
GT15-CFEX-C08SET
0.15
GT15-J71BR13
0.77
GT15-SOUT
0.08
GT15-J61BT13
0.56
GT15-DIO
0.1
Bar code reader
*2
GT15-DIOR
0.1
GT15-PRN
0.09
RFID controller
*2
GT16M-V4
0.12
*1
GT15-80FPA
0.22
GT15V-75V4
0.2
*1
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......