16. SERVO AMPLIFIER CONNECTION
16.6 Device Range that Can Be Set
16 - 23
9
ME
LSE
C
NE
T
/H
CONN
E
C
TION
(P
LC
T
O
P
L
C NE
T
W
ORK)
10
MELSE
C
N
E
T/10
C
O
NNECTION (P
LC
TO
PL
C
N
E
T
W
O
R
K
)
11
C
C
-L
ink
IE
CO
NT
RO
LLER
NE
TW
ORK
CON
N
E
CTI
O
N
12
CC-Link
IE FIELD
NETWO
RK
CONNE
CTION
13
CC-
Li
nk
CONNECTI
O
N
(IN
TEL
LI
G
E
NT
DEVI
C
E
ST
AT
IO
N)
14
CC-Lin
k
CONNECTION (V
ia G4)
15
IN
VER
TER
CONNE
C
T
ION
16
SE
R
V
O AM
P
L
IFI
E
R
CONN
E
C
T
ION
(3) MELSERVO-J2M-*DU
*1
Use PRM0 to PRM84 when writing parameters to the servo
amplifier RAM.
PRM1000 to PRM1084 are used when writing parameters to
E
2
PROM of the servo amplifier.
Use PRM1000 to PRM1084 when reading parameters to the
servo amplifier RAM.
*2
The GOT cannot read or write data from/to consecutive
devices.
POINT
POINT
POINT
Precautions for SP, OM, TMB, TMI, TMO, and TMD
devices
(1) For bit devices
Only writing is possible.
[Alternate] of a bit switch cannot be used.
Use [Set], [Reset], and [Momentary] of a bit
switch.
(2) For word devices, double word devices
Only writing is possible.
Numerical input cannot be used.
When writing, use [Word Set] of a data set switch.
The following shows correspondences between virtual
devices for servo amplifier and data of the servo
amplifier used with the GOT.
(a) Servo amplifier request
(b) Operation mode selection
(c) Instruction demand (for test operation)
(d) Basic parameter/expansion parameter
(Continued to next page)
Device name
*2
Setting range
Device
No.
represent
ation
B
it device
Servo amplifier request
(SP)
SP0
to
SP6
Decimal
Operation mode selection
(OM)
OM0
to
OM4
Instruction demand
(for test operation) (TMB)
TMB0
to
TMB1
W
o
rd
device
Basic parameter
Expansion parameter
(PRM)
*1
PRM0
to
PRM84
PRM1000 to
PRM1084
Status display (ST)
ST0
to
ST10
Alarm (AL)
AL0
AL11
to
AL21
AL200
to
AL205
AL210
to
AL215
AL230
to
AL235
Double
wor
d
device
Input signal for test
operation
(for test operation) (TMI)
TMI0
Forced output of signal pin
(for test operation) (TMO)
TMO0
Set data
(for test operation) (TMD)
TMD0
to
TMD2
Device
name
Item
Symbol
SP0
Status display data clear
―
SP1
Current alarm clear
―
SP2
Alarm history clear
―
SP3
External input signal prohibited
―
SP4
External output signal prohibited
―
SP5
External input signal resumed
―
SP6
External output signal resumed
―
Device
name
Item
Symbol
OM0
Normal mode (not test operation mode)
―
OM1
JOG operation
―
OM2
Positioning operation
―
OM3
Motorless operation
―
OM4
Output signal (DO) forced output
―
Device name
Item
Symbol
TMB0
Clears acceleration/
deceleration time constant
(test mode)
―
TMB1
Temporary stop command
(test mode)
―
Device name
Item
Symbol
*1
PRM0, PRM1000
For manufacturer setting
―
PRM1, PRM1001
Function selection 1
*OP1
PRM2, PRM1002
Auto tuning
ATU
PRM3, PRM1003
CMX Electronic gear
numerator
(Command pulse multiplying
factor numerator)
CMX
PRM4, PRM1004
Electronic gear
denominator
(Command pulse multiplying
factor denominator)
CDV
PRM5, PRM1005
In-position range
INP
PRM6, PRM1006
Position loop gain 1
PG1
PRM7, PRM1007
Position command
acceleration/deceleration
time constant
(position smoothing)
PST
PRM8 to PRM15,
PRM1008 to PRM1015
For manufacturer setting
―
PRM16, PRM1016
Alarm history clear
*BPS
PRM17 to PRM18,
PRM1017 to PRM1018
For manufacturer setting
―
PRM19, PRM1019
DRU parameter block
*BLK
PRM20, PRM1020
Function selection 2
*OP2
PRM21, PRM1021
Function selection 3
(Command pulse selection)
*OP3
PRM22, PRM1022
Function selection 4
*OP4
PRM23, PRM1023
Feed forward gain
FFC
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......