8 - 36
8. ETHERNET CONNECTION
8.4 PLC Side Setting
[Network parameter] of GX Developer
(1) Network parameter
: Necessary : As necessary : Not necessary
*1
When using Q170MCPU, set the start I/O to 0070
H
.
*2
Specify the same network No. as that of the GOT.
*3
Do not set the same station No. as that of the GOT.
*4
Set when using Ethernet module in a redundant QnPRHCPU
system.
(2) Operation setting
: Necessary : As necessary : Not necessary
*1
Because port No. 5001 is fixed, these items operate at the
following setting without relations to the setting given here.
POINT
POINT
POINT
When changing the network parameter
After writing the network parameter to the PLC CPU,
operate the PLC CPU ether turning OFF and then ON
or resetting.
Item
Set value
Setting
necessity at
GOT
connection
Network type
Ethernet (fixed)
Starting I/O No.
*1
0000
H
Network No.
*2
1
Group No.
0 (fixed)
Station No.
*3
2
Mode
Online (fixed)
Operation setting
Refer to (2)
Initial settings
(Use default value)
Open settings
Router relay parameter
Station No.<->IP information
FTP Parameters
E-mail settings
Interrupt settings
Redundant settings
*4
Routing Parameters
Refer to (3)
Item
Set value
Setting
necessity at
GOT
connection
Communication data code
*1
(Use default value)
IP address
192.168.0.19
Initial timing
*1
(Use default value)
Send frame setting
Enable Write at RUN time
*1
TCP Existence confirmation
setting
• Communication
date code
: [Binary code]
• Initial timing
: "Always wait for OPEN"
(Communication is applicable while
stopping the PLC CPU.)
• Enable Write at
RUN time
: [Enable Write at RUN time] (Writing
Data is applicable while running the
PLC CPU.)
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......