2. DEVICE RANGE THAT CAN BE SET
2.9 MELSEC-WS
2 - 17
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
D
E
VICE RA
NGE
T
H
A
T
CAN
B
E
SET
3
ACCESS
RA
N
G
E
F
O
R MONIT
O
R
ING
4
HOW T
O
MONIT
O
R
REDUNT
ANT SYS
-
TEM
5
BUS CONNECTION
6
DIR
E
CT CONNE
C
-
T
ION T
O
CP
U
7
COMP
UT
E
R
L
INK
CONNE
C
T
ION
8
E
T
HE
RN
E
T
CON
-
NE
C
T
ION
(4) When using offset specification
When setting devices using the offset function, the
device values are as follows.
(a) Input(I)
(b) Output(Q)
(c) Logic result(LQ)
(d) Logic input(LI)
(e) EFI input(EI)
(f) EFI output(EQ)
Offset
+0
+1
+2
+3
+4
+5
+6
+7
+8 to +15
+0
I1.1
I1.2
I1.3
I1.4
I1.5
I1.6
I1.7
I1.8
Fixed to 0
(OFF)
+16
I2.1
I2.2
I2.3
I2.4
I2.5
I2.6
I2.7
I2.8
+32
I3.1
I3.2
I3.3
I3.4
I3.5
I3.6
I3.7
I3.8
+48
I4.1
I4.2
I4.3
I4.4
I4.5
I4.6
I4.7
I4.8
+64
I5.1
I5.2
I5.3
I5.4
I5.5
I5.6
I5.7
I5.8
+80
I6.1
I6.2
I6.3
I6.4
I6.5
I6.6
I6.7
I6.8
+96
I7.1
I7.2
I7.3
I7.4
I7.5
I7.6
I7.7
I7.8
+112
I8.1
I8.2
I8.3
I8.4
I8.5
I8.6
I8.7
I8.8
+128
I9.1
I9.2
I9.3
I9.4
I9.5
I9.6
I9.7
I9.8
+144
I10.1
I10.2
I10.3
I10.4
I10.5
I10.6
I10.7
I10.8
+160
I11.1
I11.2
I11.3
I11.4
I11.5
I11.6
I11.7
I11.8
+176
I12.1
I12.2
I12.3
I12.4
I12.5
I12.6
I12.7
I12.8
+192
Device range error
Offset
+0
+1
+2
+3
+4
+5
+6
+7
+8 to +15
+0
Q1.1
Q1.2
Q1.3
Q1.4
Q1.5
Q1.6
Q1.7
Q1.8
Fixed to 0
(OFF)
+16
Q2.1
Q2.2
Q2.3
Q2.4
Q2.5
Q2.6
Q2.7
Q2.8
+32
Q3.1
Q3.2
Q3.3
Q3.4
Q3.5
Q3.6
Q3.7
Q3.8
+48
Q4.1
Q4.2
Q4.3
Q4.4
Q4.5
Q4.6
Q4.7
Q4.8
+64
Q5.1
Q5.2
Q5.3
Q5.4
Q5.5
Q5.6
Q5.7
Q5.8
+80
Q6.1
Q6.2
Q6.3
Q6.4
Q6.5
Q6.6
Q6.7
Q6.8
+96
Q7.1
Q7.2
Q7.3
Q7.4
Q7.5
Q7.6
Q7.7
Q7.8
+112
Q8.1
Q8.2
Q8.3
Q8.4
Q8.5
Q8.6
Q8.7
Q8.8
+128
Q9.1
Q9.2
Q9.3
Q9.4
Q9.5
Q9.6
Q9.7
Q9.8
+144
Q10.1 Q10.2 Q10.3 Q10.4 Q10.5 Q10.6 Q10.7 Q10.8
+160
Q11.1
Q11.2
Q11.3
Q11.4
Q11.5
Q11.6
Q11.7
Q11.8
+176
Q12.1 Q12.2 Q12.3 Q12.4 Q12.5 Q12.6 Q12.7 Q12.8
+192
Device range error
Offset
+0
+1
+2
+3
+4
+5
+6
+7
+0
LQ0.0
LQ0.1
LQ0.2
LQ0.3
LQ0.4
LQ0.5
LQ0.6
LQ0.7
+8
LQ1.0
LQ1.1
LQ1.2
LQ1.3
LQ1.4
LQ1.5
LQ1.6
LQ1.7
+16
LQ2.0
LQ2.1
LQ2.2
LQ2.3
LQ2.4
LQ2.5
LQ2.6
LQ2.7
+24
LQ3.0
LQ3.1
LQ3.2
LQ3.3
LQ3.4
LQ3.5
LQ3.6
LQ3.7
+32
Device range error
Offset
+0
+1
+2
+3
+4
+5
+6
+7
+0
LI0.0
LI0.1
LI0.2
LI0.3
LI0.4
LI0.5
LI0.6
LI0.7
+8
LI1.0
LI1.1
LI1.2
LI1.3
LI1.4
LI1.5
LI1.6
LI1.7
+16
LI2.0
LI2.1
LI2.2
LI2.3
LI2.4
LI2.5
LI2.6
LI2.7
+24
LI3.0
LI3.1
LI3.2
LI3.3
LI3.4
LI3.5
LI3.6
LI3.7
+32
Device range error
Offset
+0
+1
+2
+3
+8 to +15
+0
EI110
EI111
EI112
EI113
Fixed to 0
+16
EI120
EI121
EI122
EI123
+32
EI130
EI131
EI132
EI133
+48
:
+240
Fixed to 0
+256
EI210
EI211
EI212
EI213
+272
EI220
EI221
EI222
EI223
+288
EI230
EI231
EI232
EI233
Device range error
+302
Device range error
Offset
+0
+1
+2
+3 to +15
+0
EQ10
EQ11
EQ12
Fixed to 0
+16
:
+240
Fixed to 0
+256
EQ20
EQ21
EQ22
Device range error
+272
Device range error
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......