15. INVERTER CONNECTION
15.5 FREQROL Series Inverter Side Settings
15 - 35
9
ME
LSECNE
T
/H
CONN
E
CT
ION (P
LC
T
O
P
L
C NE
T
W
ORK)
10
ME
LSE
C
N
E
T/10
CONNECTION
(P
LC
T
O
P
LC NE
T
W
ORK)
11
CC
-Lin
k I
E
C
O
N
TRO
LL
E
R
NE
TW
ORK
C
O
NNE
CT
IO
N
12
CC-Lin
k IE FIELD
NETW
ORK
CONN
ECTION
13
CC-
Li
nk
CONNECTI
O
N
(INTEL
LI
G
E
NT
DEVI
CE
ST
AT
IO
N)
14
CC-Lin
k
CONNECTION (V
ia G4)
15
IN
VER
TER
CONNECTION
16
SE
R
V
O AMP
LI
F
IE
R
CONNE
C
T
ION
15.5.2 Connecting FREQROL-E500 series
Communication settings
Make the communication settings of the inverter.
Be sure to perform the inverter reset after updating each parameter.
(1) Communication port and corresponding parameters
(2) Communication settings of inverter
Set the following parameters using the PU (parameter unit).
Do not change these parameters, even though they can be monitored from the GOT.If they are changed,
communication with the GOT is disabled.
*1
Setting items are parameter names described in the manual of FREQROL-E500 series.
*2
Settings on the GOT can be changed.
When changing the settings on the GOT, be sure to change the parameters on the inverter to correspond with the GOT settings.
*3
Inverter default values (No need to change)
*4
There is no Protocol selection setting on the inverter side.
*5
The setting is required for Frequency setting command selection.
GOT connection
destination
Parameters corresponding to inverter
PU connector
Pr.79, Pr.117 to Pr.124, Pr.146, Pr.342
Setting item
*1
Parameter No.
Set value
Contents of setting
Communication station number
Pr.117
0 to 31
Communication speed
*2
Pr.118
192
*3
19200bps
Stop bit length
*2
Pr.119
10
Data length: 7bit
Stop bit length: 1bit
Parity check presence/absence
*2
Pr.120
1
Odd
Number of communication retries
Pr.121
9999
(65535)
The inverter will not come to an
alarm stop.
Communication check time interval
Pr.122
9999
Communication check
suspension
Wait time setting
Pr.123
0
0ms
CRLF presence/ absence selection
Pr.124
1
*3
With CR, without LF
Protocol selection
*4
―
―
―
Operation mode selection
Pr.79
1
*3
PU operation mode
Communication startup mode selection
*4
―
―
―
E
2
PROM write selection
Pr.342
0
*3
Written to RAM and EEPROM
Frequency setting command selection
*5
Pr.146
9999
Built-in frequency setting
potentiometer invalid
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......