10 - 12
10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
10.3 GOT Side Settings
10.3.4 Switch setting (Only when
MELSECNET/10
communication unit is used)
POINT
POINT
POINT
Switch setting of the communication unit
When using the MELSECNET/H communication unit,
the switch setting is not needed.
For details of each setting switch and LED, refer to the
following manual.
GT15 MELSECNET/10 communication unit
User's Manual
(1) Network number setting switch
(2) Group number setting switch
*1
The GOT does not use the group number.
Specify "0".
(3) Station number setting switch
(4) Mode setting switch
POINT
POINT
POINT
(1) Switch setting example
For the switch setting example, refer to the
following.
(2) When the switch setting is changed
When changing the switch setting after mounting
the MELSECNET/10 communication unit to the
GOT, reset the GOT.
(3) Self check test
Select "6" to "9" as the mode setting switch to
provide a self check test of the MELSECNET/10
communication unit.
For details, refer to the following manual.
GT15 MELSECNET/10 communication unit
User's Manual
Network number setting
switch
Description
Set value
Set the network No. of
the MELSECNET/10
communication unit.
(Default: 001)
1 to 239
Group number setting
switch
Description
Set value
Set the group No. of the
MELSECNET/10
communication unit.
(Default: 0)
0:
No group
setting (fixed)
*1
8
0
7
F
6
E
5
D
4
C
3
B
2
A
1
9
MODE
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
STATION
No.
X10
X1
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
NETWORK
No.
X10
5
0
6
1
7
2
8
3
9
4
X100
X1
5
0
6
1
7
2
8
3
9
4
GROUP No.
RUN
PC
DUAL
SW.E
M/S.E
PRM.E
CRC
OVER
AB.IF
TIME
DATA
UNDER
LOOP
SD
RD
POWER
D.LINK
T.PASS
GOT R/W
CRC
OVER
AB.IF
TIME
DATA
UNDER
LOOP
SD
RD
E
R
R
O
R
E
R
R
O
R
F.LOOP
R.LOOP
GT15-75J71LP23-Z, GT15-75J71BR13-Z
(4)
(2)
(1)
(3)
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
NETWORK
No.
X10
5
0
6
1
7
2
8
3
9
4
X100
X1
5
0
6
1
7
2
8
3
9
4
GROUP No.
Station number setting
switch
Description
Set value
Set the station No. of the
MELSECNET/10
communication unit.
Set to not duplicate other
stations in the network.
(Default: 01)
1 to 64: GT15-
75J71LP23-Z
1 to 32: GT15-
75J71BR13-Z
Mode setting switch
Description
Set value
On-line
(Default: 0)
0
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
STATION
No.
X10
X1
8
0
7
F
6
E
5
D
4
C
3
B
2
A
1
9
MODE
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......