22. MULTI-CHANNEL FUNCTION
22.3 GOT Side Settings
22 - 25
17
ROBOT
CONT
ROLLER
CONN
E
C
T
ION
18
CNC CONNECTION
19
ENER
GY M
EASU
RIN
G
UNIT/ELEC
TRIC M
UL
TI
-
MEA
S
UR
IN
G IN
STRUM
EN
T
CON
NEC
TION
20
GOT
MUL
T
I-
DROP
CONNECTION
21
M
U
LT
IP
LE
-G
T1
4,
GT
12
,
GT
11
, G
T10
CO
NNEC
TIO
N FUNCTION
22
MUL
T
I-CHANNE
L
FUNC
TION
23
F
A
TRANSP
A
R
ENT
FUNCT
ION
For the connection via the connection type selected in 22.3.3, select interfaces and communication units to be used.
Select the interfaces and communication units according to the connection type by referring to the following.
POINT
POINT
POINT
Number of units that can be installed to a GOT
The number of units that can be installed to extension interfaces differs depending on the GOT type.
Selected connection type
Reference for required interface and communication unit
• Bus connection
This section
■
GOT interface used for bus connection
• MELSECNET/H connection (PLC to PLC network)
This section
■
GOT interface used for network connection
• MELSECNET/10 connection (PLC to PLC network)
• CC-Link IE Controller Network connection
• CC-Link IE Field Network connection
• CC-Link connection (intelligent device station)
• CNC connection
(MELSECNET/10 connection (PLC to PLC network),
CC-Link connection (intelligent device station))
• Ethernet connection
This section
■
GOT interface used for Ethernet connection
• Third party PLC connection (Ethernet connection)
• MODBUS
®
/TCP connection
• Robot controller connection
• CNC connection (Ethernet connection)
• Microcomputer connection (Ethernet)
• Direct CPU connection
This section
■
GOT interface used for serial connection
• Computer link connection
• CC-Link connection (via G4)
• Third party PLC connection (serial connection)
• Third party safety controller connection
• Third party servo amplifier connection
• Third party robot controller connection
• Third party temperature controller connection
• Microcomputer Connection (Serial)
• GOT Multi- Drop Connection
• MODBUS
®
/RTU connection
• Inverter connection
• Servo amplifier connection
• CNC connection (serial connection)
• Other functions
This section
■
Interfaces and option units used for other functions
GOT
Number of units that can be installed
GT1695, GT1685, GT1675, GT1672, GT1665,
GT1662, GT1595, GT1585, GT157 , GT156
Up to 5 units can be installed (up to 4 communication units)
GT1655, GT155
Up to 3 units can be installed (up to 2 communication units)
GT12
-
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......