16. SERVO AMPLIFIER CONNECTION
16.6 Device Range that Can Be Set
16 - 33
9
ME
LSE
C
NE
T
/H
CONN
E
C
TION
(P
LC
T
O
P
L
C NE
T
W
ORK)
10
MELSE
C
N
E
T/10
C
O
NNECTION (P
LC
TO
PL
C
N
E
T
W
O
R
K
)
11
C
C
-L
ink
IE
CO
NT
RO
LLER
NE
TW
ORK
CON
N
E
CTI
O
N
12
CC-Link
IE FIELD
NETWO
RK
CONNE
CTION
13
CC-
Li
nk
CONNECTI
O
N
(IN
TEL
LI
G
E
NT
DEVI
C
E
ST
AT
IO
N)
14
CC-Lin
k
CONNECTION (V
ia G4)
15
IN
VER
TER
CONNE
C
T
ION
16
SE
R
V
O AM
P
L
IFI
E
R
CONN
E
C
T
ION
(f) Alarm
(g) External I/O signal
(h) Current position latch data
(i) The value of the general-purpose register (Rx)
(j) The value of the general-purpose register (Dx)
(k) Input signal for test operation (for test operation)
(l) Forced output of signal pin (for test operation)
(m) Set data (for test operation)
Device
name
Item
Symbol
AL0
Current alarm number
―
AL1
Detailed data of current alarms
―
AL11
Servo status when alarm occurs Current
position
―
AL12
Servo status when alarm occurs Command
position
―
AL13
Servo status when alarm occurs Command
remaining distance
―
AL14
Servo status when alarm occurs Program
Number
―
AL15
Servo status when alarm occurs Step Number
―
AL16
Servo status when alarm occurs Cumulative
feedback pulses
―
AL17
Servo status when alarm occurs
Servo motor speed
―
AL18
Servo status when alarm occurs Droop pulses
―
AL19
Servo status when alarm occurs Override
―
AL20
Servo status when alarm occurs Torque limit
voltage
―
AL21
Servo status when alarm occurs
Regenerative load ratio
―
AL22
Servo status when alarm occurs Effective
load ratio
―
AL23
Servo status when alarm occurs Peak load
ratio
―
AL24
Servo status when alarm occurs
Instantaneous torque
―
AL25
Servo status when alarm occurs Within one-
revolution position
―
AL26
Servo status when alarm occurs ABS counter
―
AL27
Servo status when alarm occurs
Load inertia moment ratio
―
AL28
Servo status when alarm occurs Bus voltage
―
AL200
Alarm number from Alarm History
most recent alarm
―
AL201
Alarm number from Alarm History
first alarm in past
―
AL202
Alarm number from Alarm History
second alarm in past
―
AL203
Alarm number from Alarm History
third alarm in past
―
AL204
Alarm number from Alarm History
fourth alarm in past
―
AL205
Alarm number from Alarm History
fifth alarm in past
―
AL210
Alarm occurrence time in alarm history
most recent alarm
―
AL211
Alarm occurrence time in alarm history
first alarm in past
―
AL212
Alarm occurrence time in alarm history
second alarm in past
―
AL213
Alarm occurrence time in alarm history
third alarm in past
―
AL214
Alarm occurrence time in alarm history
fourth alarm in past
―
AL215
Alarm occurrence time in alarm history
fifth alarm in past
―
AL230
Detailed alarm from Alarm History
most recent alarm
―
AL231
Detailed alarm from Alarm History
first alarm in past
―
AL232
Detailed alarm from Alarm History
second alarm in past
―
AL233
Detailed alarm from Alarm History
third alarm in past
―
AL234
Detailed alarm from Alarm History
fourth alarm in past
―
AL235
Detailed alarm from Alarm History
fifth alarm in past
―
Device
name
Item
Symbol
DI0
Input device statuses
―
DI1
External input pin statuses
―
DI2
Statuses of input devices switched on
through communication
―
DO0
Output device statuses
―
DO1
External output pin statuses
―
Device
name
Item
Symbol
LD1
Current position latch data
―
Device name
Item
Symbol
RR1, RR1001
The value of the general-
purpose register (R1)
―
RR2, RR1002
The value of the general-
purpose register (R2)
―
RR3, RR1003
The value of the general-
purpose register (R3)
―
RR4, RR1004
The value of the general-
purpose register (R4)
―
Device name
Item
Symbol
RD1
The value of the general-
purpose register (D1)
―
RD2
The value of the general-
purpose register (D2)
―
RD3
The value of the general-
purpose register (D3)
―
RD4
The value of the general-
purpose register (D4)
―
Device name
Item
Symbol
TMI0
Input signal for test operation
―
Device name
Item
Symbol
TMO0
Forced output of signal pin
―
Device
name
Item
Symbol
TMD0
Writes the speed (test mode)
―
TMD1
Writes the acceleration/deceleration time
constant(test mode)
―
TMD2
Writes the moving distance in pulses(test
mode)
―
Device
name
Item
Symbol
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......