16 - 36
16. SERVO AMPLIFIER CONNECTION
16.6 Device Range that Can Be Set
(g) I/O setting parameter
*1
For the parameters prefixed by an asterisk (*), setting
becomes effective when the power is turned off once and
back on after setting the parameter data.
(h) Status display
(i) Alarm
Device name
Item
Symbol
*1
PD1, PD1001
Input signal automatic ON
selection 1
*DIA1
PD2, PD1002
For manufacturer setting
―
PD3, PD1003
Input signal device selection 1
(CN1-15)
*DI1
PD4, PD1004
Input signal device selection 2
(CN1-16)
*DI2
PD5, PD1005
Input signal device selection 3
(CN1-17)
*DI3
PD6, PD1006
Input signal device selection 4
(CN1-18)
*DI4
PD7, PD1007
Input signal device selection 5
(CN1-19)
*DI5
PD8, PD1008
Input signal device selection 6
(CN1-41)
*DI6
PD9, PD1009
For manufacturer setting
―
PD10, D1010
Input signal device selection 8
(CN1-43)
*DI8
PD11, PD1011
Input signal device selection 9
(CN1-44)
*DI9
PD12, PD1012
Input signal device selection 10
(CN1-45)
*DI10
PD13, PD1013
Output signal device selection 1
(CN1-22)
*DO1
PD14, PD1014
Output signal device selection 2
(CN1-23)
*DO2
PD15, PD1015
Output signal device selection 3
(CN1-24)
*DO3
PD16, PD1016
Output signal device selection 4
(CN1-25)
*DO4
PD17, PD1017
For manufacturer setting
―
PD18, PD1018
Output signal device selection 6
(CN1-49)
*DO6
PD19, PD1019
Response level setting
*DIF
PD20, 1020
Function selection D-1
*DOP1
PD21, PD1021
For manufacturer setting
―
PD22, PD1022
Function selection D-3
*DOP3
PD23, PD1023
For manufacturer setting
―
PD24, PD1024
Function selection D-5
*DOP5
PD25 to PD30,
PD1025 to PD1030
For manufacturer setting
―
Device
name
Item
Symbol
ST0
Cumulative feedback pulses
―
ST1
Servo motor speed
―
ST2
Droop pulses
―
ST3
Cumulative command pulses
―
ST4
Command pulse frequency
―
ST5
Analog speed command voltage/limit voltage
―
ST6
Analog torque command voltage/limit voltage
―
ST7
Regenerative load ratio
―
ST8
Effective load ratio
―
ST9
Peak load ratio
―
ST10
Instantaneous torque
―
ST11
Within one-revolution position
―
ST12
ABS counter
―
ST13
Load inertia moment ratio
―
ST14
Bus voltage
―
Device name
Item
Symbol
AL0
Current alarm number
―
AL1
Detailed data of current alarms
―
AL11
Servo status when alarm occurs cumulative
feedback pulses
―
AL12
Servo status when alarm occurs
servo monitor speed
―
AL13
Servo status when alarm occurs droop pulses
―
AL14
Servo status when alarm occurs cumulative
command pulses
―
AL15
Servo status when alarm occurs command
pulse frequency
―
AL16
Servo status when alarm occurs analog
speed command voltage
/limit voltage
―
AL17
Servo status when alarm occurs
analog torque command voltage
/limit voltage
―
AL18
Servo status when alarm occurs
regenerative load ratio
―
AL19
Servo status when alarm occurs effective
load ratio
―
AL20
Servo status when alarm occurs peak load
ratio
―
AL21
Servo status when alarm occurs
instantaneous torque
―
AL22
Servo status when alarm occurs within one-
revolution position
―
AL23
Load inertia moment ratio ABS counter
―
AL24
Servo status when alarm occurs
load inertia moment ratio
―
AL25
Servo status when alarm occurs bus voltage
―
AL200
Alarm number from alarm history
most recent alarm
―
AL201
Alarm number from alarm history
first alarm in past
―
AL202
Alarm number from alarm history
second alarm in past
―
AL203
Alarm number from alarm history
third alarm in past
―
AL204
Alarm number from alarm history
fourth alarm in past
―
AL205
Alarm number from alarm history
fifth alarm in past
―
AL210
Alarm occurrence time in alarm history
most recent alarm
―
AL211
Alarm occurrence time in alarm history
first alarm in past
―
AL212
Alarm occurrence time in alarm history
second alarm in past
―
AL213
Alarm occurrence time in alarm history
third alarm in past
―
AL214
Alarm occurrence time in alarm history
fourth alarm in past
―
AL215
Alarm occurrence time in alarm history
fifth alarm in past
―
AL230
Detailed alarm from alarm history
most recent alarm
―
AL231
Detailed alarm from alarm history
first alarm in past
―
AL232
Detailed alarm from alarm history
second alarm in past
―
AL233
Detailed alarm from alarm history
third alarm in past
―
AL234
Detailed alarm from alarm history
fourth alarm in past
―
AL235
Detailed alarm from alarm history
fifth alarm in past
―
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......