(4) Setting of the mask type (MELSEC-FX)
Set the item for monitoring or writing only the specified
bits of the buffer memory.
HINT
HINT
HINT
Mask type
The mask type is effective when using for the buffer
memories divided per 4 bits, such as an analog input
block.
(a) Mask type 0
Monitor and write the buffer memory value directly.
(b) Mask type 1
• (For 16 bits)
Monitor and write only b0 to b3 of the buffer
memory.
Example:
The monitor value is 0001
H
when monitoring
BM=4321
H
as mask type 1.
BM0=0001
H
when writing input value 4321
H
to
BM0=0000
H
as mask type 1.
• (For 32 bits)
Monitor and write only b0 to b3 and b16 to 19 of
the buffer memory.
Example:
The monitor value is 00050001
H
when monitoring
BM0=87654321
H
as mask type 1.
BM0=00050001
H
when writing input value
87654321
H
to BM0=00000000
H
as mask type 1.
(c) Mask type 2
• (For 16 bits)
Monitor and write only b4 to b7 of the buffer
memory.
Example:
The monitor value is 0002
H
when monitoring
BM0=4321
H
as mask type 2.
BM0=0010
H
when writing input value 4321
H
to
BM0=0000
H
as mask type 2.
• (For 32 bits)
Monitor and write only b4 to b7 and b20 to 23 of
the buffer memory.
Example:
The monitor value is 00060002
H
when monitoring
BM0=87654321
H
as mask type 2.
BM0=00500010
H
when writing input value
87654321
H
to BM0=00000000
H
as mask type 2.
(d) Mask type 3
• (For 16 bits)
Monitor and write only b8 to b11 of the buffer
memory.
Example:
The monitor value is 0003
H
when monitoring
BM0=4321
H
as mask type 3.
BM0=0100
H
when writing input value 4321
H
to
BM0=0000
H
as mask type 3.
BM0
Monitor value
H
4
3
2
1
0
0
0
1
H
BM0
(Before writing)
(After writing)
BM0
Input value
H
4
3
2
1
0
0
0
0
H
0
0
0
1
H
H
BM0
8
7
6
5
4
3
2
1
0
0
0
5
0
0
0
1
H
Monitor value
H
BM0
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
H
Input value
BM0
0
0
0
5
0
0
0
1
H
(Before writing)
(After writing)
BM0
Monitor value
H
4
3
2
1
0
0
0
2
H
BM0
(Before writing)
(After writing)
BM0
Input value
H
4
3
2
1
0
0
0
0
H
0
0
1
0
H
H
BM0
8
7
6
5
4
3
2
1
0
0
0
6
0
0
0
2
H
Monitor value
H
BM0
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
H
Input value
BM0
0
0
5
0
0
0
1
0
H
(Before writing)
(After writing)
BM0
Monitor value
H
4
3
2
1
0
0
0
3
H
BM0
(Before writing)
(After writing)
BM0
Input value
H
4
3
2
1
0
0
0
0
H
0
1
0
0
H
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......