16 - 22
16. SERVO AMPLIFIER CONNECTION
16.6 Device Range that Can Be Set
(a) Servo amplifier request
(b) Operation mode selection
(c) Basic parameter/expansion parameter
*2
For the parameters prefixed by an asterisk (*), setting
becomes effective when the power is turned off once and
back on after setting the parameter data.
(d) Status display
(e) Alarm
(f) External I/O signal
(g) Forced output of signal pin (for test operation)
Device name
Item
Symbol
SP1
Current alarm clear
―
SP2
Alarm history clear
―
Device name
Item
Symbol
OM0
Normal mode
(not test operation mode)
―
OM4
Output signal (DO) forced
output
―
Device name
Item
Symbol
*2
PRM0, PRM1000
Serial communication
function selection,
alarm history clear
*BPS
PRM1, PRM1001
Regenerative brake option
selection
*REG
PRM2, PRM1002
Function selection 1
*OP1
PRM3, PRM1003
Analog monitor 1 output
MD1
PRM4, PRM1004
Analog monitor 2 output
MD2
PRM5, PRM1005
Analog monitor 3 output
MD3
PRM6, PRM1006
Analog monitor 1 offset
MO1
PRM7, PRM1007
Analog monitor 2 offset
MO2
PRM8, PRM1008
Analog monitor 3 offset
MO3
PRM9, PRM1009
Function selection 2
*OP2
PRM10, PRM1010
Interface unit serial
communication station No.
selection
*ISN
PRM11, PRM1011
Slot 1 serial communication
station No. selection
*DSN1
PRM12, PRM1012
Slot 2 serial communication
station No. selection
*DSM2
PRM13, PRM1013
Slot 3 serial communication
station No. selection
*DSM3
PRM14, PRM1014
Slot 4 serial communication
station No. selection
*DSN4
PRM15, PRM1015
Slot 5 serial communication
station No. selection
*DSN5
PRM16, PRM1016
Slot 6 serial communication
station No. selection
*DSN6
PRM17, PRM1017
Slot 7 serial communication
station No. selection
*DSN7
PRM18, PRM1018
Slot 8 serial communication
station No. selection
*DSN8
PRM19, PRM1019
Parameter write inhibit
*BLK
PRM20, PRM1020
Serial communication
time-out selection
SIC
PRM21 to PRM29
PRM1021 to PRM1029
For manufacturer setting
―
Device name
Item
Symbol
ST0
Regenerative load ratio
―
ST1
Bus voltage
―
ST2
Peak bus voltage
―
Device
name
Item
Symbol
AL0
Current alarm number
―
AL11
Servo status when alarm occurs
regenerative load factor
―
AL12
Servo status when alarm occurs bus voltage
―
AL13
Servo status when alarm occurs peak bus
voltage
―
AL200
Alarm number from alarm history
most recent alarm
―
AL201
Alarm number from alarm history
first alarm in past
―
AL202
Alarm number from alarm history
second alarm in past
―
AL203
Alarm number from alarm history
third alarm in past
―
AL204
Alarm number from alarm history
fourth alarm in past
―
AL205
Alarm number from alarm history
fifth alarm in past
―
AL210
Alarm occurrence time in alarm history
most recent alarm
―
AL211
Alarm occurrence time in alarm history
first alarm in past
―
AL212
Alarm occurrence time in alarm history
second alarm in past
―
AL213
Alarm occurrence time in alarm history
third alarm in past
―
AL214
Alarm occurrence time in alarm history
fourth alarm in past
―
AL215
Alarm occurrence time in alarm history
fifth alarm in past
―
AL230
Detailed alarm from alarm history
most recent alarm
―
AL231
Detailed alarm from alarm history
first alarm in past
―
AL232
Detailed alarm from alarm history
second alarm in past
―
AL233
Detailed alarm from alarm history
third alarm in past
―
AL234
Detailed alarm from alarm history
fourth alarm in past
―
AL235
Detailed alarm from alarm history
fifth alarm in past
―
Device
name
Item
Symbol
DI0
External input pin statuses CN1A/CN1B
―
DI1
External input pin statuses CN5
―
DI2
External input pin statuses CN4A/CN4B
―
DO0
External output pin statuses CN1A/CN1B
―
DO1
External output pin statuses CN1A/CN1B
―
Device
name
Item
Symbol
TMO0
Forced output of signal pin
―
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......