2.2 MELSEC iQ-F
The table below shows the device ranges in [MELSEC iQ-
F] as the controller type.
*1
Available for file register of block No. switched with the RSET
instruction.
*2
Only the intelligent function module on the station connected
to GOT can be specified.
Set within the address range of the buffer memory existing in
the target intelligent function module.
*3
The device No. must be set in multiples of 16.
Device name
Setting range
Device No.
representation
B
it device
Input (X)
X0 to X1777
Octal
Output (Y)
Y0 to Y1777
Internal relay (M)
M0 to M32767
Decimal
Latch relay (L)
L0 to L32767
Step relay (S)
S0 to S4095
Annunciator (F)
F0 to F32767
Link relay (B)
B0 to B7FFF
Hexadecimal
Timer
Contact (TT)
TT0 to TT1023
Decimal
Coil (TC)
TC0 to TC1023
Counter
Contact (CT)
CT0 to CT1023
Coil (CC)
CC0 to CC1023
Long counter
Contact
(LCT)
LCT0 to LCT1023
Coil (LCC)
LCC0 to LCC1023
Special relay (SM)
SM0 to SM9999
Retentive timer
Contact (SS)
SS0 to SS1023
Coil (SC)
SC0 to SC1023
Link special relay (SB)
SB0 to SB7FFF
Hexadecimal
The bit specification of the
word device
(except Timer, Counter,
Retentive timer, Index register
(Z))
Setting range of
each word device
―
W
ord device
Data register (D)
D0 to D7999
Decimal
Special data register (SD)
SD0 to SD11999
Link register (W)
W0 to W7FFF
Hexadecimal
Timer (current value) (TN)
TN0 to TN1023
Decimal
Counter (current value)(CN)
CN0 to CN1023
Retentive timer (current value)
(SN)
SN0 to SN1023
Link special register (SW)
SW0 to SW7FFF
Hexadecimal
File register (R)
*1
R0 to R32767
Decimal
Index register (Z)
Z0 to Z23
Buffer memory
(Intelligent function module)
(G)
*2
G0 to G262143
The word specification of the
bit device
*3
(except Timer, Counter,
Retentive timer)
Setting range of
each bit devices
―
Doubl
e wo
rd
device
Long counter (current value)
(LCN)
*3
LCN0 to LCN1023
-
Index register (LZ)
LZ0 to LZ11
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......