7 - 14
7. COMPUTER LINK CONNECTION
7.2 System Configuration
*1
For details on the system configuration on the serial communication module side, refer to the following manual.
Serial Communication Module User's Manual (Modem Function Additional Version)
For the system configuration on the computer link module side, refer to the following manual.
Computer Link Module (Com. link func./Print. func.) User’s Manual
When connecting to a computer link module, set the communication driver to [AJ71C24/UC24].
*2
Connect it to the RS-232 interface (built into GOT). It cannot be mounted on GT1655 and GT155 .
*3
For details of the GOT multi-drop connection, refer to the following.
*4
Use the RS-232 connection model.
*5
Use the RS-422 connection model.
PLC
Connection cable
GOT
Number of
connectable
equipment
Model name
Serial communication
module/Computer link
module
*1
Communication
type
Cable model
Max.
distance
Option device
Model
MELSEC-QnA
(QnASCPU)
A1SJ71QC24
A1SJ71QC24N
A1SJ71QC24N1
RS-422
1200m
- (Built into GOT)
1 GOT for 1
serial
communication
module
GT09-C30R4-6C(3m)
GT09-C100R4-6C(10m)
GT09-C200R4-6C(20m)
GT09-C300R4-6C(30m)
or
1200m
GT16-C02R4-9S
GT15-RS2T4-9P
*2
GT15-RS4-9S
- (Built into GOT)
500m
GT01-RS4-M
*3
-
1200m
- (Built into GOT)
*5
MELSEC-QnA
(QnASCPU)
A1SJ71UC24-R2
A1SJ71C24-R2
A1SJ71UC24-PRF
A1SJ71C24-PRF
RS-232
GT09-C30R2-9P(3m)
or
15m
- (Built into GOT)
1 GOT for 1
computer link
module
GT15-RS2-9P
GT01-RS4-M
*3
-
15m
- (Built into GOT)
*4
A1SJ71UC24-R4
A1SJ71C24-R4
RS-422
500m
- (Built into GOT)
GT09-C30R4-6C(3m)
GT09-C100R4-6C(10m)
GT09-C200R4-6C(20m)
GT09-C300R4-6C(30m)
or
500m
GT16-C02R4-9S
GT15-RS2T4-9P
*2
GT15-RS4-9S
- (Built into GOT)
GT01-RS4-M
*3
-
500m
- (Built into GOT)
*5
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......