10 - 14
10. CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER
10.5 Indicating Controller Side Setting
10.5.4 Station No. settings
Set each station number so that no station number
overlaps.
The station number can be set without regard to the cable
connection order. There is no problem even if station
numbers are not consecutive.
(1) Direct specification
When setting the device, specify the station number of
the indicating controller of which data is to be changed.
(2) Indirect specification
When setting the device, indirectly specify the station
number of the indicating controller of which data is to be
changed using the 16-bit GOT internal data register
(GD10 to GD25).
When specifying the station No. from 100 to 115 on GT
Designer3, the value of GD10 to GD25 compatible to
the station No. specification will be the station No. of
the indicating controller.
(3) All station specification
Target station differs depending on write-in operation or
read-out operation.
• For write-in operation, all station will be a target.
In the WORD BIT write-in operation, only the
indicating controller whose station No. is the same as
host address is applicable. For details of host address
setting, refer to the following.
10.4.1 Setting communication interface
(Communication settings)
• In the read-out operation, only the indicating controller
whose station No. is the same as host address is
applicable.
For details of host address setting, refer to the
following.
10.4.1 Setting communication interface
(Communication settings)
Specification range
0 to 94
Specification
station NO.
Compatible
device
Setting range
100
GD10
0 to 94
For the setting other than the above, error
(dedicated device is out of range) will
occur.
101
GD11
102
GD12
103
GD13
104
GD14
105
GD15
106
GD16
107
GD17
108
GD18
109
GD19
110
GD20
111
GD21
112
GD22
113
GD23
114
GD24
115
GD25
GOT
Station
No.3
Station
No.7
Station
No.1
Station
No.15
Station
No.6
Examples of station number setting
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......