6.2.7
PLC Side Setting
POINT
POINT
POINT
KEYENCE PLC
For details of KEYENCE PLC, refer to the following
manual.
KEYENCE PLC user's Manual
Connecting KV-3000,KV-1000
*1
There is no transmission speed setting on the PLC side.The
transmission speed of the PLC side is automatically adjusted
to that of the GOT side.
Connecting to KV-700
Connecting to KV-L20R, KV-L20,.KV-L20V
(1) Communication settings
*1
Only transmission speeds available on the GOT side are
shown.
*2
The transmission speed setting must be consistent with that
of the GOT side.
For the transmission speed setting on the GOT side, refer to
the following.
Setting communication interface (Communication
*3
Set the station No. according to the host address on the
GOT side.
For the Host Address setting on the GOT side, refer to the
following.
Setting communication interface (Communication
(2) Setting DIP switches
Set the DIP switches.
(a) When using KV-L20R or KV-L20
• RS232/RS422/RS485 switch (For port 2)
(For KV-L20R)
(For KV-L20)
• Terminator setting switch
Set when carrying out RS-422 communication.
Model name
Reference
PLC CPU
KV-3000
KV-1000
KV-700
Multi-communication unit
KV-L20R
KV-L20
KV-L20V
Setting items
Set value
Transmission Speed
9600 to 115200 bps
*1
Data bit
8bits
Parity bit
Even
Stop bit
1bit
Setting items
Set value
Transmission Speed
9600bps
Data bit
8bits
Parity bit
Even
Stop bit
1bit
Setting items
Set value
Communication mode
KV mode (Upper link)
Transmission speed
*1*2
4800bps, 9600bps, 19200bps, 38400bps,
57600bps, 115200bps
Data bit
8bits
Parity bit
Even
Stop bit
1bit
Station No.
*3
0 to 9
Settings
For RS-232
communication
For RS-422
communication
RS-232C
RS-422A
485(4)
Settings
For RS-232
communication
For RS-422
communication
RS-232C
RS-422A
Settings
When multi-
communication unit
is a terminal
When multi-
communication unit
is not a terminal
ON
OFF
Terminator
setting switch
Port 1 (RS232)
Port 2
(RS232/RS422/RS485)
RS232/RS422/RS485 switch
(For port 2)
485(4)
232C 422A 485(2)
232C 422A VT
ON
OFF
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......