4 - 42
4. CONNECTION TO OMRON PLC
4.4 Device Range that Can Be Set
4.4.2
OMRON PLC (OMRON
SYSMAC CS/CJ)
*1
When executing the touch switch function set during the bit
specification of the word device, do not write any data to the
word device through the sequence program.
*2
Writing or reading the extension data memory using multiple
banks is not allowed.
*3
Timer (current value) and counter (current value) are valid
within the range of 0 to 9999.
(This applies to the 16 bit/32 bit device data.)
*4
This is not supported by GT10.
*5
“Timer (current value)” and “Counter (current value)” are
handled as BCD values by the PLC.
If the connection form between the PLC and the GOT is
serial, however, they are handled as unsigned binary 16-bit
data by the GOT. Set the data type of “Monitor object” in the
GOT to “Unsigned BIN16”.
Device name
Setting range
Device No.
representation
Bi
t de
vi
ce
I/O relay/internal
auxiliary relay (...)
..000000 to ..614315
D
Hexadecimal
Data link relay (LR)
LR00000 to LR19915
Auxiliary memory
relay (AR)
AR000000 to AR147115
AR1000000 to AR1153515
Holding relay (HR)
HR00000 to HR51115
Internal auxiliary
relay/Work relay
(WR)
WR00000 to WR51115
Timer contact (TIM)
TIM0000 to TIM4095
Decimal
Counter contact
(CNT)
CNT0000 to CNT4095
Word device bit
*1*4
Specified bit of the following
word devices
(except data link relay,
auxiliary memory relay,
holding relay
and internal auxiliary relay.)
-
Wo
rd
d
ev
ic
e
I/O relay/internal
auxiliary relay (...)
..0000 to ..6143
Decimal
Data link relay (LR)
LR000 to LR199
Auxiliary memory
relay (AR)
AR0000 to AR1471
AR10000 to AR11535
Holding relay (HR)
HR000 to HR511
Internal auxiliary
relay/Work relay
(WR)
WR000 to WR511
Data memory (DM)
DM00000 to DM32767
Timer (current value)
(TIM)
*3*5
TIM0000 to TIM4095
Counter (current
value) (CNT)
*3*5
CNT0000 to CNT4095
Extension data
memory (EM current
bank)
*2
EM00000 to EM32767
Extension data
memory (E0 to EC:
13banks)
*2
E000000 to E032767
:
E1800000 to E1832767
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......