3. CONNECTION TO AZBIL CONTROL EQUIPMENT
3.3 Connection Diagram
3 - 45
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
C
O
NNECTION T
O
IAI
ROBO
T
CO
N
T
RO
L
L
E
R
3
CON
N
EC
TI
O
N
T
O
AZBIL
C
O
N
T
ROL
EQU
IP
M
EN
T
4
CONNECTION T
O
OMRON PLC
5
CONNECTI
O
N T
O
OMRO
N TEMPERA
TURE
CONTROL
LE
R
6
CONNECTION T
O
KE
YENCE PL
C
7
CONNE
C
T
ION T
O
KO
YO
EI
PLC
8
CONN
E
CT
ION T
O
JT
EK
T PL
C
RS485 connection diagram 33)
*1
Pin No. of control equipment differs depending on the model. Refer to the following table
*2
Terminating resistor should be provided for an Interface converter and a control equipment which will be terminals.
*3
Connect FG grounding to the single-sided end of a cable shield line.
*4
Set the 2-wire/4-wire terminating resistor setting switch of the RS-232/485 signal conversion adaptor as follows.
2-wire type/4-wire type: 2-wire type (1Pair)
Terminating resistor
: OPEN
1.4.4 Setting the RS-232/485 signal conversion adaptor
Precautions when preparing a cable
(1) Cable length
The length of the RS-485 cable must be 500m or less.
(2) GOT side connector
For the GOT side connector, refer to the following.
1.4.1 GOT connector specifications
(3) AZBIL control equipment side connector
Use the connector compatible with the AZBIL control
equipment side module.
For details, refer to the user's manual of the AZBIL
control equipment.
Connecting terminating resistors
(1) GOT side
When connecting a PLC to the GOT, a terminating
resistor must be connected to the GOT.
(a) For GT16, GT15, GT12
Set the terminating resistor by operating the
terminating resistor setting switch.
(b) For GT14, GT11
Set the terminating resistor by operating the
terminating resistor selector switch.
For the procedure to set the terminating resistor, refer
to the following.
1.4.3 Terminating resistors of GOT
(2) AZBIL control equipment side
When connecting a AZBIL control equipment to the
GOT, a terminating resistor must be connected.
3.5 Control Equipment Side Setting
SDA
SDB
RDA
RDB
SG
DA
DB
SG
*3
*3
*1
*1
DA
DB
SG
GOT side
*4
Control equipment side
Terminating resistor(150
Ω
1/2W)
*2
Control
equipment
side
Signal name
Model of control equipment
SDC45/46
CMS
CMF015
MQV
MPC
MVF
RX
Pin No.
Pin No.
Pin No.
Pin No.
Pin No.
DA
C10
5
7
1
1
DB
C11
6
8
2
2
SG
C12
10
9
7
3
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......