10. CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER
10.2 System Configuration
10 - 3
9
CONN
E
C
TION
T
O
S
H
ARP PLC
10
C
O
NN
ECTI
ON
T
O
SHI
N
KO
TECHN
OS IN
DIC
ATI
NG
C
O
NT
ROLLE
R
11
CONNECTION T
O
CH
INO
CONTROLLE
R
12
CONNECTION T
O
T
O
SHI
B
A
PL
C
13
CONNECTION T
O
T
O
SH
IB
A M
A
C
H
IN
E
PLC
14
CONNECTION T
O
P
A
NA
SONIC S
E
R
V
O
A
M
PL
IF
IE
R
15
CONNE
CTION T
O
PA
NA
SONIC
INDUSTRI
AL
DE
VI
CES
SU
NX
PLC
10.2 System Configuration
10.2.1 Connecting to ACS-13A, JC, JCM-33A, JIR-301-M, PCD-300 Series, PC-
900 Series (PC-955-[ ]/M,C5, PC-935-[ ]/M,C5)
For the RS-232 connection (via interface converter)
*1
The communication converter is a product manufactured by Shinko Technos Co., Ltd.For details of the product, contact Shinko
Technos Co., Ltd.
For the RS-485 connection
Shinko Technos Controller
Communication driver
GOT
Interface
converter
Connection cable 1)
Connection cable 2)
ACS13A,JC,
JCM-33A,JIR-301-M,
PCD-300 series,
PC-955-□/M,C5,
PC-935-□/M,C5
ACS13A,JC,
JCM-33A,JIR-301-M,
PCD-300 series,
PC-955-□/M,C5,
PC-935-□/M,C5
Indicating controller
Connection cable 1)
Communication
converter
*1
Connection cable 2)
GOT
Number of
connectable
equipment
Model name
Communication
Type
Cable model
Connection
diagram number
Max.
distance
Cable model
Connection
diagram number
Max.
distance
Option
device
Model
ACS13A
JC
JCM-33A
JIR-301-M
PCD-300 Series
PC-955- /M,C5
PC-935- /M,C5
RS-232
1,200m
IF-400
RS-232C CFP-
C2
*1
15m
- (Built
into GOT)
31
indicating
controllers
for 1 GOT
GT15-
RS2-9P
Shinko Technos Controller
Communication driver
GOT
Connection cable
ACS13A,JC,
JCM-33A,JIR-301-M,
PCD-300 series,
PC-955-□/M,C5,
PC-935-□/M,C5
ACS13A,JC,
JCM-33A,JIR-301-M,
PCD-300 series,
PC-955-□/M,C5,
PC-935-□/M,C5
Indicating controller
Connection cable
GOT
Number of
connectable
equipment
Model name
Communication
Type
Cable model
Connection diagram number
Max.
distance
Option device
Model
ACS13A
JC
JCM-33A
JIR-301-M
PCD-300 Series
PC-955- /M,C5
PC-935- /M,C5
RS-485
500m
GT15-RS4-TE
31 indicating
controllers for 1
GOT
500m
- (Built into GOT)
500m
FA-LTBGTR4CBL05 (0.5m)
FA-LTBGTR4CBL10 (1m)
FA-LTBGTR4CBL20 (2m)
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......