4. CONNECTION TO OMRON PLC
4.2 Serial Connection
4 - 31
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
C
O
NNECTION T
O
IAI
ROBO
T
CO
N
T
RO
L
L
E
R
3
CONNECTION T
O
AZBI
L C
O
NTR
O
L
EQUI
PMENT
4
CONNECTION T
O
OMRON PLC
5
CONNECTI
O
N T
O
OMRO
N TEMPERA
TURE
CONTROL
LE
R
6
CONNECTION T
O
KE
YENCE PL
C
7
CONNE
C
T
ION T
O
KO
YO
EI
PLC
8
CONN
E
CT
ION T
O
JT
EK
T PL
C
4.2.17 Connecting to serial
communication unit
Device settings
Write the following set values to devices of each PLC
CPU and initialize each port using a peripheral tool or
DM monitor.
m = 30000 + (100 unit No.)
*1
Only transmission speeds available on the GOT side are
shown.
*2
Set the same transmission speed of the GOT.
*3
Set the host link station No. according to the Host Address
on the GOT side.
4.2.18 Connecting to communication
board, serial communication
board (CQM1-SCB41)
Device settings
Write the following set values to devices of each PLC
CPU and initialize each port using a peripheral tool or
DM monitor.
*1
Only transmission speeds available on the GOT side are
shown.
*2
Set the same transmission speed as that of the GOT side.
*3
Set the host link station No. according to the Host Address
on the GOT side.
Device name
Set value
Port 1
Port 2
DM (m)
DM
(m+10)
8000
H
(fixed): The settings are:
Port setting: Arbitrary setting
Serial communication mode: Host link
Start bit: 1bit
Data bit: 7bits
Stop bit: 2bits
Parity: Even
DM
(m+1)
DM
(m+11)
DM
(m+2)
DM
(m+12)
8000
H
(fixed)
DM
(m+3)
*3
DM
(m+13)
*3
8000
H
to 801F
H
b15 to b8
b7 to b0
1) Transmission speed
*1*2
00
H
: 9600bps
08
H
: 38400bps
05
H
: 4800bps
09
H
: 57600bps
06
H
: 9600bps
0A
H
: 115200bps
07
H
: 19200bps
0
H
1)
Device name
Set value
Port B
Port A
DM6550
DM6555
0001
H
(fixed)
DM6551
DM6556
DM6552
DM6557
0000 (fixed)
DM6553
*3
DM6558
*3
0000 to 0031
b15 to b8
b7 to b0
1) Transmission speed
*1*2
02
H
:4800bps
03
H
:9600bps
04
H
:19200bps
2)
1)
2) Frame format setting
03
H
(fixed): The settings are:
Start bit :1 bit
Data length:7 bits
Stop bit :2 bits
Parity :Even bits
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......