8.6 Device Range that Can Be Set
The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
POINT
POINT
POINT
Program number setting (when PC3JG, PC3J or
PC3JD is used)
Setting of a program number is allowed for the devices
indicated below.
Internal relay (M), keep relay (K), link relay (L), special
relay (V), edge detection (P), timer (T), counter (C),
data register (D), link register (R), special register (S),
current value register (N)
8.6.1
JTEKT PLC
(JTEKT TOYOPUC-PLC)
*1
Overlapped device designation of an input (X, EX, GX) and
an output (Y, EY, GY), or a timer (T, ET) and a counter (C,
EC) is not allowed.(Example: X0000 and Y0000, EX0000
and EY0000)
*2
To store a setting value of T (timer) or C (counter), use TCS.
Setting value of a timer and a counter is stored in TCS.
(TCS cannot be used if a timer or a counter is not in a
program.)
*3
GX, GY, GM and EB can be used only in the PC3JG
separate mode.
Access to GX, GY, GM and EB through a link module is not
possible.
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
Program No.
Sets the number of the program for which
the device is set.
Information
Displays the device type and setting range which are
selected in [Device].
Network
Set the monitor target of the set device.
Station No.
Set this item when monitoring the PLC of
the specified station No. (octal)
Device name
Setting range
Device
No.
represen
tation
Bit
de
vi
ce
Input (X)
*1
X000 to X7FF
Hexadeci
mal
Output (Y)
*1
Y000 to Y7FF
Link relay (L)
L000 to L7FF
Internal relay (M)
M000 to M7FF
Keep relay (K)
K000 to K2FF
Edge detection (P)
P000 to P1FF
Timer (T)
*1
T000 to T1FF
Counter (C)
*1
C000 to C1FF
Special relay (V)
V000 to V0FF
Extended input (EX)
*1
EX000 to EX7FF
Extended output (EY)
*1
EY000 to EY7FF
Extended internal relay (EM)
EM0000 to EM1FFF
Extended keep-relay (EK)
EK000 to EKFFF
Extended special relay (EV)
EV000 to EVFFF
Extended timer (ET)
*1
ET000 to ET7FF
Extended counter (EC)
*1
EC000 to EC7FF
Extended link relay (EL)
EL0000 to EL1FFF
Extended edge detection (EP)
EP000 to EPFFF
Extended input 2 (GX)
*1*3
GX0000 to GXFFFF
Extended output 2 (GY)
*1*3
GY0000 to GYFFFF
Extended internal relay (GM)
*3
GM0000 to GMFFFF
Word device bit
Specified bits of the following
word devices
(Excluding EB and TCS)
W
o
rd d
e
vice
Data register (D)
D0000 to D2FFF
Hexadeci
mal
Link register (R)
R0000 to R07FF
Current value register (N)
N0000 to N01FF
Special register (S)
S0000 to S03FF
File register (B)
B0000 to B1FFF
Extended present value
register (EN)
EN0000 to EN07FF
Extended setup value register
(H)
H0000 to H07FF
Extended special register (ES)
ES0000 to ES07FF
Extended data register (U)
U0000 to U7FFF
Extended buffer register
(EB)
*3
EB00000 to EB07FFF
EB08000 to EB0FFFF
EB10000 to EB17FFF
EB18000 to EB1FFFF
Setup value register (TCS)
*2
TCS0000 to TCS01FF
Word of bit devices above
Converting bit devices into word
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......