11. CONNECTION TO CHINO CONTROLLER
11.5 Controller Side Setting
11 - 29
9
CONN
E
C
TION
T
O
S
H
ARP PLC
10
C
O
NN
ECTI
ON
T
O
SHI
N
KO
TECHN
OS IN
DIC
ATI
NG
C
O
NT
ROLLE
R
11
CONNECTION T
O
CH
INO
CONTROLLE
R
12
CONNECTION T
O
T
O
SHI
B
A
PL
C
13
CONNECTION T
O
T
O
SH
IB
A M
A
C
H
IN
E
PLC
14
CONNECTION T
O
P
A
NA
SONIC S
E
R
V
O
A
M
PL
IF
IE
R
15
CONNE
CTION T
O
PA
NA
SONIC
INDUSTRI
AL
DE
VI
CES
SU
NX
PLC
11.5.8 Connecting to SE3000
Key Lock setting
To write the Digital and the Analog parameters, set the
Key Lock setting.
Communication settings
Make the communication settings using the
engineering software package (PASS)
*1
Avoid duplication of the station No. with any of the other
units.
*2
Adjust the settings with GOT settings.
*3
Station No. and Transmission speed can also be set by
switch SW1.
Setting by Switch (SW1)
Station No. and Transmission speed can be set.
(1) Station No.
(2) Transmission speed
Setting by Switch (SW2)
11.5.9 Connecting to JU
Key Lock setting
To write the Digital and the Analog parameters, set the
Key Lock setting.
Communication settings
Set the communication settings with controller key
operation.
*1
Avoid duplication of the station No. with any of the other
units.
*2
Adjust the settings with GOT settings.
Item
Set value
Protocol
MODBUS RTU
Station No.
*1*3
1 to 31
Transmission speed
*2*3
9600bps, 19200bps
Data bit
8bits (fixed)
Parity bit
*2
Even, Odd, Non
Stop bit
*2
1bit, 2bits
Transmission code
Binary (fixed)
Error check
CRC-16 (fixed)
SW1-1
SW1-2
SW1-3
SW1-4
SW1-5
Station No.
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
1
OFF
ON
OFF
OFF
OFF
2
ON
ON
OFF
OFF
OFF
3
:
:
ON
OFF
ON
ON
ON
29
OFF
ON
ON
ON
ON
30
ON
ON
ON
ON
ON
31
SW1-6
SW1-7
communication port
Transmission speed
OFF
OFF
Upper communication
9600bps
OFF
ON
Upper communication
19200bps
ON
OFF
ENG
-
ON
ON
User setting inhibited
12
3
ON
45678
SW1
SW2
Front side (Terminal side)
Rear side (DIN rail side)
RS232C
RS422A/485
Item
Set value
Protocol
rtU
Station No.
*1
1 to 99
Transmission speed
*2
9600bps, 19200bps
Character
*2
(Bit length, Parity bit, Stop bit)
[8N1]: 8bit, None, 1bit
[8N2]: 8bit, None, 2bit
[8E1]: 8bit, Even, 1bit
[8E2]: 8bit, Even, 2bit
[8O1]: 8bit, Odd, 1bit
[8O2]: 8bit, Odd, 2bit
DIN rail side
Upside
422A
/485
232C
Terminal side
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......