1 - 18
1. PREPARATORY PROCEDURES FOR MONITORING
1.3 Option Devices for the Respective Connection
1.3.7
Installing a unit on another unit (Checking the unit installation position)
This section describes the precautions for installing units on another unit.
For the installation method of each unit, refer to the User's Manual for the communication unit and option unit you are
using. For the method for installing a unit on another unit, refer to the following.
User's Manual of GOT used
Calculating consumed current
For using multiple extension units, a bar code reader, or a RFID controller, the total current for the extension units,
bar code reader, or RFID controller must be within the current that the GOT can supply.
For the current that the GOT can supply and the current for the extension units, bar code reader, or RFID controller,
refer to the following tables. Make sure that the total of consumed current is within the capacity of the GOT.
(1) Current supply capacity of the GOT
(2) Current consumed by an extension unit/barcode reader/RFID controller
*1
Value used for calculating the current consumption of the multi-channel function.
For the specifications of the unit, refer to the manual included with the unit.
*2
When the GOT supplies power to a barcode reader or a RFID controller from the standard interface, add their consumed current.
(Maximum value is less than 0.3 A)
GOT type
Current supply
capacity
(A)
GOT type
Current supply
capacity
(A)
GT1695M-X
2.4
GT1595-X
2.13
GT1685M-S
2.4
GT1585V-S
1.74
GT1675M-S
2.4
GT1585-S
1.74
GT1675M-V
2.4
GT1575V-S
2.2
GT1675-VN,
GT1672-VN
2.4
GT1575-S
2.2
GT1665M-S
2.4
GT1575-V,
GT1572-VN
2.2
GT1665M-V
2.4
GT1565-V,
GT1562-VN
2.2
GT1662-VN
2.4
GT1555-V
1.3
GT1655-V
1.3
GT1555-Q,
GT1550-Q
1.3
Module type
Consumed
current
(A)
Module type
Consumed
current
(A)
GT15-QBUS,
GT15-QBUS2,
GT15-75QBUSL,
GT15-75QBUS2L
0.275
*1
GT15V-75V4
0.2
*1
GT15-ABUS,
GT15-ABUS2,
GT15-75ABUSL,
GT15-75ABUS2L
0.12
GT16M-R2
0
*1
GT15-RS2-9P
0.29
GT15V-75R1
0.2
*1
GT15-RS4-9S
0.33
GT16M-V4R1
0.12
*1
GT15-RS4-TE
0.3
GT15V-75V4R1
0.2
*1
GT15-RS2T4-9P
0.098
GT16M-ROUT
0.11
*1
GT15-J71E71-100
0.224
GT15V-75ROUT
0.11
GT15-J71GP23-SX
1.07
GT16M-MMR
0.27
*1
GT15-J71GF13-T2
0.96
GT15-CFCD
0.07
GT15-J71LP23-25
0.56
GT15-CFEX-C08SET
0.15
GT15-J71BR13
0.77
GT15-SOUT
0.08
GT15-J61BT13
0.56
GT15-DIO
0.1
Bar code reader
*2
GT15-DIOR
0.1
GT15-PRN
0.09
RFID controller
*2
GT16M-V4
0.12
*1
GT15-80FPA
0.22
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......