background image

 

 
 
 
 
 
 
 
 
 
 

iPECS eMG800 

 

Hardware Description & Installation Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Please read this manual carefully before operating System. 

Retain it for future reference. 

 

Summary of Contents for eMG800

Page 1: ...iPECS eMG800 Hardware Description Installation Manual Please read this manual carefully before operating System Retain it for future reference...

Page 2: ...ccordance with these agencies you may be required to provide information such as the following to the end user European Union Declarations of Conformity Ericsson LG Enterprise Co Ltd declare that the...

Page 3: ...nterference in which case the user may be required to take adequate measures WARNING This equipment generates and uses R F energy and if not installed and used in accordance with the Instruction Manua...

Page 4: ...Caution for DTIB12C 24C 1 8 Jan 2022 S W version 6 0 x Applied S W version 6 0 x General Update Copyright 2015 Ericsson LG Enterprise Co Ltd All Rights Reserved This material is copyrighted by Ericsso...

Page 5: ...4 7 CO Loop 8 2 4 8 Wireless DECT Terminal 8 2 4 9 MPB VOIP 8 2 4 10 VOIP channels VOIB 9 2 4 11 Other System Specifications 9 2 5 System Capacity 10 2 5 1 System Maximum Call Capacity 11 2 6 Install...

Page 6: ...2 1 Switch and LED Functions 37 4 3 2 2 BRIB Installation 38 4 3 2 3 BRIB Wiring 38 4 3 2 4 Serial Port 39 4 3 3 E1R2 PRIB Primary Rate Interface Board 40 4 3 3 1 Switch and LED Functions 41 4 3 3 2 E...

Page 7: ...5 3 VOIB128 Voice over Internet protocol Board 128 channel 67 4 5 3 1 Switch and LED Functions 67 4 5 3 2 VOIB128 Installation 67 4 6 Serial to Audio Cable Specification 68 4 6 1 Serial to Audio Cable...

Page 8: ...iPECS eMG800 Hardware Description and Installation Manual Issue 1 8 iv 6 STARTING THE IPECS eMG800 87 6 1 Initializing Databases 87 7 TROUBLESHOOTING 90 8 Open Source Software Notice 92...

Page 9: ...other heat source This product should not be placed in a built in installation without proper ventilation This product should be operated only from the type of power source indicated on the product la...

Page 10: ...nly be installed and serviced by qualified service personnel When a failure occurs which exposes any internal parts disconnect the power supply cord immediately and return this system to your dealer T...

Page 11: ...em including system specifications and capacity Section 3 KSU Installation Instructions for installation of the iPECS eMG800 cabinets Section 4 Board Installation Detailed instructions for installing...

Page 12: ...rt license Unified System software Simple and easy to learn and use Powerful UCP features and Applications available to hybrid system cost effectively Features of the iPECS eMG800 System include Seaml...

Page 13: ...escription and Installation Manual Issue 1 8 5 2 2 System Connection Diagram The following figure System Connection Diagram shows the components that make up the iPECS eMG800 solution Figure 2 2 1 Sys...

Page 14: ...d 4 channels BRIB4 4 So To Interface Board 8 channels PRIB DCO Interface Board 1 PRI or 1 E1R2 30chs 1 T1 24chs Extension Boards SLIB12 12 SLT Interface Board SLIB12C 12 SLT Interface Board RJ21 SLIB2...

Page 15: ...Humidity 0 80 non condensing 2 4 3 System Electrical ITEM SPECIFICATION PSU Power Supply AC Voltage Input 100 240 Volt AC 47 63Hz AC Power 350W AC Input Fuse 6 3A 250Volt AC DC Output Voltage 5 30Vol...

Page 16: ...0Hz DTMF Dialing Frequency Deviation Less than 1 8 Signal Rise Time Max 5ms Tone Duration on time Min 50ms Inter digit Time Min 30ms Pulse Dialing Pulse Rate 10 pps Break Make Ratio 60 40 66 33 or 50...

Page 17: ...g T 38 Echo cancellation G 168 2 4 11 Other System Specifications ITEM DESCRIPTION SPECIFICATION CPU M86295G Cortex A9 32bit 900MHz Switching Device ACT2 Custom Mixed Signal ASIC Device RTC Back up Du...

Page 18: ...VMIB AAIB 1 Host mode Memory stick only CPT CID CO DTMF Detection channels 32 channels MPB 32 channels MPB PFT Circuit 1 LCOB4 LCOB8 LCOB12 WTIB 3 TDM DECT Base 24 IP DECT Base 128 DECT phones 192 It...

Page 19: ...LT PRI BRI CO IP w VOIB128 1st KSU 40 126 1 126 2 120 40 60 120 128 Total 132 120 248 132 1st KSU 2nd KSU 88 270 270 240 88 132 264 128 Total 276 264 392 276 1st 2nd 3rd KSU 136 414 414 360 136 204 40...

Page 20: ...ult the database 7 Configure the system see iPECS Administration Programming manual 8 Verify the installation 2 7 Types of Connectors The following chart displays the various types of connectors emplo...

Page 21: ...System is designed for wall mounting or a freestanding rack Avoid installing in the following places In direct sunlight and extremely hot cold or humid places optimal temperature range 0 to 40C Place...

Page 22: ...prongs on the plug are deformed The power cord s inner wires are exposed broken etc The power cord s coating has a crack The power cord is overheating The power cord is damaged If the above symptoms f...

Page 23: ...dware Description and Installation Manual Issue 1 8 15 3 KSU Installation 3 1 BKSU Unpacking Open the box and verify the items shown in Figure 3 1 1 BKSU Carton Contents are included Figure 3 1 1 BKSU...

Page 24: ...MG800 Hardware Description and Installation Manual Issue 1 8 16 3 2 EKSU Unpacking Open the box and verify the items shown in Figure 3 2 1 EKSU Carton Contents are included Figure 3 2 1 EKSU Carton Co...

Page 25: ...rdware Description and Installation Manual Issue 1 8 17 3 3 KSU Diagram Exterior and Dimension For reference purposes Figure 3 3 1 shows the exterior and dimensions of the KSU Figure 3 3 1 KSU Exterio...

Page 26: ...Rack Mount brackets to each side of the KSU with the eight 8 screws provided 2 Insert screws with washers through the Rack Mount bracket flange on each side of the cabinet 3 As required thread screws...

Page 27: ...plugs 4 Tighten the screws leaving about 5 mm 0 2 inches exposed 5 Hook the Wall Bracket onto installed screws and tighten screws 6 Install the Rack Mount brackets to each side of the KSU with the eig...

Page 28: ...ting Place the EKSU on top of the BKSU making sure to align the feet of the EKSU with the cavities in the lower KSU For 19 Rack mounting Insert screws and washers through the Rack Mounting bracket on...

Page 29: ...iPECS eMG800 Hardware Description and Installation Manual Issue 1 8 21 Figure 3 5 1 Expansion KSU installation Figure 3 5 2 Expansion KSU Wall Mounting...

Page 30: ...iPECS eMG800 Hardware Description and Installation Manual Issue 1 8 22 Figure 3 5 3 Expansion KSU Rack Mounting...

Page 31: ...independent of the 2nd KSU powered Off however the 3rd KSU cannot work without the 2nd KSU powered On It is recommended that the iPECS eMG800 be reset if the PSU in an EKSU is power cycled or turned...

Page 32: ...d if the AC power is re connected or if the battery voltage is too low to maintain full system operation The length of time that the System will operate on the batteries is dependent on several elemen...

Page 33: ...ndle pull the PSU from the KSU To install the new PSU 1 Insert the PSU along the guide rails on the rear side of iPECS eMG800 2 Slide PSU into the KSU to firmly seat the PSU in the backplane connector...

Page 34: ...ystem from static electricity do not directly touch the boards to discharge static touch a grounded object or wear a grounding strap To install the Board 1 If required install any option modules on th...

Page 35: ...e 4 2 1 MPB If an MPB is not installed DC Power 5V 30V will not feed to the backplane and other boards or EKSUs The following devices and functions are included on the MPB Main Processor MINDSPEED Cor...

Page 36: ...orrectly replaced Be sure to dispose of used batteries according to manufacturer instructions and or local government regulations 4 2 1 Switch Connector and LED Functions The MPB has various switches...

Page 37: ...al PRIB BRIBs are installed the default clock priority will be as follows unless modified by the Admin PGM207 Boards PRIB BRIB2 or BRIB4 Internal Clock KSUs 1 st KSU 2 nd KSU 3 rd KSU Slot Slot 1 Slot...

Page 38: ...he System database and maintenance functions as well as the basic VoIP channel if installed The LAN connector pin outs are shown in the chart below and should be wired to an appropriate Ethernet switc...

Page 39: ...sing UTP cable Tag or number wiring for maintenance Table 4 2 5 1 1 Alarm and Relay Contact Connector CONNECTION PIN SIGNAL NAME RJ45 1 ALARM T 2 ALARM R 3 Not used 4 Not used 5 Relay1 T 6 Relay1 R 7...

Page 40: ...32 Monitor Wiring The RS 232 female connector which is a DCE Data Communication Equipment is used for various output functions SMDR Traffic Reports etc and can be used to access the System database an...

Page 41: ...is NOT field replaceable Table 4 2 8 1 RJ45 Pin Assignment DKT 1 to 6 Connectors CONNECTOR PIN SIGNAL NAME RJ45 1 2 3 Not used 4 DKT T 5 DKT R 6 7 8 Not used Table 4 2 8 2 RJ45 Pin Assignment SLT 1 to...

Page 42: ...ower Failure Transfer PFT circuit that can be wired to an SLIB port for PFT service The below figure shows LCOB8 which other than the added interface circuits is identical to LCOB 4 and 12 Figure 4 3...

Page 43: ...the LCOB in the guide rails of the desired slot 3 Tighten thumbscrews to hold the board firmly in place 4 3 1 3 LCOB Wiring The CO Line Tip and Ring terminations are located on the center pair of each...

Page 44: ...hannels The BRIB is compatible with ETSI 300 012 and ITU T recommendations I 430 supporting S Subscriber or T Trunk interfaces As shown in Figure 4 3 2 1 the S interface of the BRIB acts as the NT Net...

Page 45: ...de Note The default setting is T Mode for all switches SW1 3 and SW1 4 are for BRIB4 only Table 4 3 2 1 2 BRIB Terminating Resister 100 Ohm SWITCH FUNCTION ON OFF SW6 1 Line 1 TX resistor Terminate Op...

Page 46: ...B cannot simultaneously support both the T and S mode all ports on the BRIB must be set in the same mode T or S The BRIB board can be installed in any universal slot of any KSU the 1st slot of the BKS...

Page 47: ...llation Manual Issue 1 8 39 Figure 4 3 2 3 1 ISDN Connections Basic Rate 4 3 2 4 Serial Port The PRIB includes an Audio jack connected to a Serial port The serial port is used for diagnostic purposes...

Page 48: ...e Slot 0 is allocated to frame alignment sync and Time Slot 16 is allocated to the signaling channel the other time slots are available for allocation to the B channel The CEPT frame has four signalin...

Page 49: ...annels in use OFF All channels Idle 4 3 3 2 E1 PRIB Installation Before inserting the PRIB set SW1 and SW4 Dip switches to match the Telco provided service The PRIB board can be installed in any unive...

Page 50: ...r to the digital line termination point using UTP cable Tag or number wiring for maintenance Table 4 3 3 3 1 PRI Port CONNECTOR PIN SIGNAL RJ45 1 RX 2 RX 4 TX 5 TX 3 6 7 8 Not used Figure 4 3 3 3 1 E1...

Page 51: ...upporting DID TIE Line and Loop or Ground Start are implemented The DID and TIE Line operation support Immediate Delayed and Wink start signaling protocols The Telco interface must provide BZ8S line c...

Page 52: ...channels idle 4 3 4 2 T1 PRIB Installation Before inserting the T1 PRIB set SW1 and SW4 Dip switches to match the Telco provided service Note that the PRIB supports ESF Extended Super Frame framing an...

Page 53: ...Wiring Diagram below Wire the TX and RX pins of the RJ45 connector to the digital line termination point at the CSU using UTP cable Tag or number wiring for maintenance Table 4 3 4 3 1 T1 PRI Port CO...

Page 54: ...12 analog Single Line Telephone ports and the SLIB24 with 24 SLT ports In both cases the SLT ports are each terminated in an RJ45 connector The SLIB provides FSK ITU T V 23 or Bell 202 or DTMF ITU T Q...

Page 55: ...he desired slot 3 Tighten thumbscrews to hold the board firmly in place 4 4 1 3 SLIB Wiring The SLT is terminated to the center pair of each RJ45 connector A separate RJ45 is provided for each SLT por...

Page 56: ...LIB24C with 24 SLT ports The SLIBC is identical to the SLIB except the SLT ports of the SLIBC are terminated in a 25 pair RJ21 female connector The SLIBC provides FSK ITU T V 23 or Bell 202 or DTMF IT...

Page 57: ...6th port in use OFF Idle LD5 The status of 5th port or 17th port ON Blue 5th port in use ON Yellow Green 17th port in use ON Blush white 5th and 17th port in use OFF Idle LD6 The status of 6th port or...

Page 58: ...of the BKSU is for the MPB only 1 Assure Power is OFF 2 Slide the SLIBC in the guide rails of the desired slot 3 Tighten thumbscrews to hold the board firmly in place 4 4 2 3 SLIBC Wiring Each SLT po...

Page 59: ...iPECS eMG800 Hardware Description and Installation Manual Issue 1 8 51 12 37 12 13 38 13 14 39 14 15 40 15 16 41 16 17 42 17 18 43 18 19 44 19 20 45 20 21 46 21 22 47 22 23 48 23 24 49 24 25 50...

Page 60: ...available in two 2 models the DTIB12 with 12 Digital Key Telephone Interface ports and the DTIB24 with 24 DKT ports Each port provides power and signaling to the DKT over a single wire pair Each DKT p...

Page 61: ...the desired slot 3 Tighten thumbscrews to hold the board firmly in place 4 4 3 3 DTIB Wiring A separate RJ45 is provided for each DKT port on the DTIB 12 or 24 connectors DKT ports terminate on the c...

Page 62: ...one Interface ports and the DTIB24 with 24 DKT ports The DTIBC is identical to the DTIB except the DKT ports of the DTIBC are terminated to an RJ21 connector Each port provides power and signaling to...

Page 63: ...e 4th and 16th port Use OFF Idle LD5 The status of 5th port or 17th port ON Blue 5th port Use ON Yellow Green 17th port Use ON Blush white 5th and 17th port Use OFF Idle LD6 The status of 6th port or...

Page 64: ...he BKSU is for the MPB only 1 Assure Power is OFF 2 Slide the DTIBC in the guide rails of the desired slot 3 Tighten thumbscrews to hold the board firmly in place 4 4 4 3 DTIBC Wiring Each DKT port is...

Page 65: ...iPECS eMG800 Hardware Description and Installation Manual Issue 1 8 57 12 37 12 13 38 13 14 39 14 15 40 15 16 41 16 17 42 17 18 43 18 19 44 19 20 45 20 21 46 21 22 47 22 23 48 23 24 49 24 25 50...

Page 66: ...e up the System DECT solution WTIB4 WTIB8 board Up to three WTIB4s or WTIB8s can be installed in the iPECS eMG800 The WTIB4 and WTIB8 have 4 or 8 Base Station ports respectively Base Station GDC 600BE...

Page 67: ...the System DECT Base Stations and is the interface between Base Stations and other resources and features of iPECS eMG800 iPECS eMG800 supports three 3 WTIBs Each port on the WTIB terminates to an RJ4...

Page 68: ...D NORMAL LABEL 1 ON Master WTIB Toggle Slave 1 WTIB OFF Slave 2 WTIB M S 2 When Nios CPU is normal TMR LED toggles every 100msec TMR 3 ON DSP Echo cancellation enabled OFF DSP Echo cancellation disabl...

Page 69: ...the WTIB is terminated to an RJ45 connector wired as shown in the pin out chart below Separate wiring is required for the TX and RX pairs Power is delivered from the WTIB to the Base Station over the...

Page 70: ...Power feed 6 RX GND Table 4 4 5 5 2 Base Station CONNECTOR PIN SIGNAL NAME FUNCTION RJ11 5 6 Not used 1 TX GND Transmit Data Gnd Power feed 4 TX GND 2 RX 30V Receive Data 30VDC power 3 RX 30V Figure 4...

Page 71: ...TING USER GREETING VMIB 8 System Greeting 0 5hrs User Message 100 Hours AAIB 8 System Greeting 0 5hrs User Message None VMIB and AAIB have a standard USB connector that is used to back up System and U...

Page 72: ...slot of the BKSU is for MPB only 1 Assure Power is OFF 2 Slide the VMIB AAIB in the guide rails of the desired slot 3 Tighten thumbscrews to hold the board firmly in place 4 5 1 3 VMIB and AAIB Wiring...

Page 73: ...ects to a standard IEEE 10 100 Base T Ethernet switch port and supports auto negotiation for speed 10MBps or 100Mbps and full or half duplex operation The VOIB supports various codecs g 711 g 726 g 72...

Page 74: ...or on the front panel The connector is terminated as a standard EIA 568B MDI Media Dependent Interface port Referring to the pin out chart below Using UTP cable wire each VOIB TX and RX pairs to the t...

Page 75: ...ious codecs g 711 g 726 g 729 g 723 1 T 38 for IP FAX and Echo Cancellation g 168 Figure 4 5 3 1 VOIB128 4 5 3 1 Switch and LED Functions Table 4 5 3 1 1 Connector Jack and Switch Functions SWITCH CON...

Page 76: ...4 6 1 Audio Jack Serial Specification 4 6 1 Serial to Audio Cable Wiring Connection to the Serial port through the Audio connector is made with a Serial to Audio cable The cable should be terminated...

Page 77: ...Wall Mount Wiring To dress wiring for a Wall mount installation 1 Ensure all boards are installed and that wiring is complete 2 Using the supplied Cable Ties tie all wiring cables and Power cord if d...

Page 78: ...all boards are installed and that wiring is complete 2 Using the supplied Cable Ties tie all wiring cables and Power cord if desired together in a neat bundle 3 Using the supplied Cable Ties tie the b...

Page 79: ...lexible Button w Display LDP 7016D 16 Flexible Button w Display LDP 7024D 24 Flexible Button w Display LDP 7024LD 24 Flexible Button w Large Display LDP 7048DSS 48 Button DSS DLS Console LDP DPB Door...

Page 80: ...exible button pages to represent 24 total flexible buttons LIP 9048DSS 48 flexible buttons with tri color LED LIP 9070 Premium Touch Screen IP Phone 7 Inch TFT color LCD Android OS WVGA resolution Vid...

Page 81: ...KT or Console The wall outlet for the DKT or Console should be connected back to an appropriate DTIB or MPB DSIU DKT port Refer to the pin out chart below and Figure 5 1 1 1 Wire the wall outlet 1st p...

Page 82: ...nd a PC port The LAN port is connected to an Ethernet switch port and the PC port is connected to the LAN port of a PC The LIP phones are wired to any 10 100 or 1000 Base T Ethernet switch port with a...

Page 83: ...Display Description MODE R L LOCAL CHANGE Registration mode use to set Remote mode PHONE IP ADDRESS DOT Use the dial pad to enter the fixed IP address use DHCP for dynamic addressing PHONE NET MASK D...

Page 84: ...e Box is wired using screw terminals in the box The terminals are wired to any available DKT port except for the first DKT port 1 Refer to Figure 5 1 3 2 1 and the pin out chart below 2 Loosen the scr...

Page 85: ...Series DSS BLF Console is available in three 3 models 12 button w paper labels LIP 8012DSS 12 button w LCD LIP 8012LSS and 48 button w paper labels LIP 8048DSS Up to four 4 consoles can be connected...

Page 86: ...LIP phone housing 5 For additional DSS BLF Consoles repeat the procedure connecting one console to the previous console A maximum of three consoles can be supported by LIP 8000 series phone 6 For eac...

Page 87: ...own in the below and described as follows LIP 9012DSS has 12 flexible buttons with tri color LED The DSS button kit uses a paper label for the button designations LIP 9024DSS has 24 flexible buttons w...

Page 88: ...rst assure the phone is NOT connected to power For convenience you may wish to remove the handset and foot stand this simplifies the Button kit installation 2 On the right side of the phone remove the...

Page 89: ...ype of communication supported 2 SIP SIP protocol type of communication supported PoE Class The PoE Power over Ethernet Class is indicated the class of the Powered Device PD and CLASS switch is used t...

Page 90: ...to connect the LIP 9048 DSS and phone firmly together 4 At the back of LIP 9048 DSS and phone remove the rubber plug from the Accessory Expansion Module AEM port 5 Plug the 12 Pin cable into the AEM p...

Page 91: ...ill flash when there is new activity under a button on the page You can press the page button at any time to change the flexible button page view 1048idss has 48 flexible buttons with tri color LED Th...

Page 92: ...the handset and foot stand this simplifies the DSS installation 2 Align the DSS and phone as shown in the drawing 3 Connect the DSS Connecting Cable to the phone 4 Push the DSS into the phone until th...

Page 93: ...t from slipping when wall mounted 5 2 2 LIP 8000 8000E 1000i Series Wall Mount LIP 8000 8000E series and 1000i phones except of 1080i incorporate wall mount into the base of the phone housing Using th...

Page 94: ...essure until it clicks into place 5 LIP 9000 only Install the Button kit wall mount bracket if required in the same manner as the bracket for the phone 6 Mark and drill two 7mm holes for plastic wall...

Page 95: ...eetings or Name recordings To initialize the database the System must be powered up with the Mode switch ON Place the MPB Mode switch in the OFF position Assure the AC power cord for each KSU is plugg...

Page 96: ...ation Code chart below Press the HOLD SAVE button to store the entry Table 6 1 2 Nation Code Listing NATION CODE NATION CODE NATION CODE Argentina 54 Honduras 504 Peru 51 Australia 61 Hong Kong 852 Ph...

Page 97: ...ng the Country Code you must reset the System Press the TRANS PGM button Dial 499 Press Flexible button 2 Press HOLD SAVE button The System will proceed to initialize the database with the new Country...

Page 98: ...ing board Bad connection between the DSIU DTIB and DKT Terminals Check the connection between the board and the DKT Assure proper wiring terminations Repair any broken connection between the Board and...

Page 99: ...re the PSU is plugged in that the AC power is delivered to the outlet and the Fuse Breaker is operational Noise on External MOH and Paging port Induced noise on the wire between the System and the amp...

Page 100: ...ral Public License GPLv2 linux kernel GNU General Public License GPLv2 busybox GNU General Public License GPLv2 openldap OpenLDAP Public License BSD style openssl OpenSSL License and the original SSLe...

Page 101: ...urchasing iPECS eMG800 The contents of this document are subject to revision without notice due to continued progress in methodology design and manufacturing Ericsson LG Enterprise shall have no liabi...

Reviews: