![iPECS eMG800 Hardware Description & Installation Manual Download Page 46](http://html1.mh-extra.com/html/ipecs/emg800/emg800_hardware-description-and-installation-manual_2088622046.webp)
iPECS eMG800
Hardware Description and Installation Manual
Issue 1.8
38
Table 4.3.2.1-4 LED Indication, BRIB2
NO
FUNCTION
STATUS
LD1
LD3
Line 1 status
Red: ON = Error
Blue: ON = In-use, OFF = Idle
LD2
LD4
Line 2 status
Red: ON = Error
Blue: ON = In-use, OFF: = Idle
Table 4.3.2.1-5 LED Indication, BRIB4
NO
FUNCTION
STATUS
LD1
LD5
Line 1 status
Red: ON = Error
Blue: ON = In-use, OFF = Idle
LD2
LD6
Line 2 status
Red: ON = Error
Blue: ON = In-use, OFF = Idle
LD3
LD7
Line 3 status
Red: ON = Error
Blue: ON = In-use, OFF = Idle
LD4
LD8
Line 4 status
Red: Error
Blue: ON = In-use, OFF = Idle
4.3.2.2
BRIB Installation
Before installation of the BRIB, set the Mode, Terminating Resistor, and Power Feed Switches for each BRIB
Line. Note that the BRIB cannot simultaneously support both the T and S mode, all ports on the BRIB must be
set in the same mode, T or S.
The BRIB board can be installed in any universal slot of any KSU; the 1st slot of the BKSU is for the MPB only.
Assure Power is OFF
Slide the BRIB in the guide rails of the desired slot.
Tighten thumbscrews to hold the board firmly in place.
4.3.2.3
BRIB Wiring
A separate RJ45 connector is provided for each BRI line supported by the BRIB. Referring to the pin-out chart
and Figure 4.3.2.3 1 below,
Wire the TX and RX pins of each RJ-45 connector to the BRI digital line termination point using UTP
cable.
Tag or number wiring for maintenance.
Table 4.3.2.3-1 RJ45
CONECTOR
PIN
NAME(T-mode)
FUNCTION
NAME(S-mode)
FUNCTION
RJ45
1,2,7,8
Reserved
3
TX+
Transmit Data
RX+
Receive Data
4
RX+
Receive Data
TX+
Transmit Data
5
RX-
Receive Data
TX-
Transmit Data
6
TX-
Transmit Data
RX-
Receive Data