![iPECS eMG800 Hardware Description & Installation Manual Download Page 72](http://html1.mh-extra.com/html/ipecs/emg800/emg800_hardware-description-and-installation-manual_2088622072.webp)
iPECS eMG800
Hardware Description and Installation Manual
Issue 1.8
64
4.5.1.1
Switch, and LED Functions
Table 4.5.1.1-1 Switch Functions
SWITCH
FUNCTION
REMARK
SW1
4-POLE Dip Switch (Function: not defined)
Default: Off
SW3
Reset switch
SW2 & 4
-
Table 4.5.1.1-2 LED Indication
LED
FUNCTION
REMARK
LD1
Normal operation indication (Activity Indication)
Blink (blue Color)
LD2
Memory Full (ON
– Full, OFF – Usable)
AAIB
– Not used
LD3
Record (ON
– Active, OFF – Idle)
LD4
Play (ON
– Active, OFF – Idle)
RJ45-LD1
(Green/Orange)
ON
– Link, Blink – Data Transfer
RJ45-LD2 (Yellow)
ON - 100Mbps, OFF
– 10Mbps
4.5.1.2
VMIB and AAIB Installation
VMIB and AAIB have no switches or connectors that are field useable. VMIB and AAIB can be installed in any
universal slot of any KSU; the 1st slot of the BKSU is for MPB only.
1)
Assure Power is OFF
2)
Slide the VMIB/AAIB in the guide rails of the desired slot.
3)
Tighten thumbscrews to hold the board firmly in place.
4.5.1.3
VMIB and AAIB Wiring
There is no wiring required for proper operation of the VMIB or AAIB.
4.5.1.4
VMIB and AAIB LAN Connector
The VMIB and AAIB include an RJ45 for connection to a 10/100 Base-T Ethernet (IEEE 802.3) connection.
The port supports auto negotiation for speed (10 or 100 Mbps) and full or half-duplex operation. If need be, the
RJ45 is wired as indicated in the RJ45 pin-out chart below.
Table 4.5.1.4-1 VMIB & AAIB RJ45 Pin-out Chart
CONNECTOR
PIN
SIGNAL NAME
FUNCTION
RJ45
4,5,7,8
Not used
1
TX+
Transmit Data
2
TX-
Transmit Data
3
RX-
Receive Data
6
RX+
Receive Data
4.5.1.5
Serial Port
The VMIB and AAIB include an Audio jack connected to a Serial port. The serial port is used for diagnostic
purposes. For wiring information, refer to section 4.6.