iPECS eMG800
Hardware Description and Installation Manual
Issue 1.8
47
4.4.1.1
LED Functions
LED
FUNCTION
REMARK
LD1
ACT, Activation or Normal Operating
Blink (Blue Color)
LD2
IN USE
ON: one or ports in use
OFF: All channels, Idle
4.4.1.2
SLIB Installation
The SLIB has no switches or connectors that are field useable. The SLIB can be installed in any universal slot
of any KSU; the 1st slot of the BKSU is for the MPB only.
1)
Assure Power is OFF.
2)
Slide the SLIB in the guide rails of the desired slot.
3)
Tighten thumbscrews to hold the board firmly in place.
4.4.1.3
SLIB Wiring
The SLT is terminated to the center pair of each RJ45 connector. A separate RJ45 is provided for each SLT
port on the SLIB (12 or 24 connectors).
Refer to the pin-out chart below,
Wire pins 4 and 5 of the RJ45 connector to the SLT termination point using UTP cable. The maximum
total wire length is 7500M/24Kft of 22 AWG wire or 5000M/16Kft of 24 AWG wire. For information on
wiring the SLT, refer to section 5.1.2.2.
Tag or number wiring for maintenance.
Table 4.4.1.3.1 SLIB 12/24
CONNECTOR
PIN
SIGNAL NAME
FUNCTION
RJ45
1,2,3
Not used
4
SLT_RX
Receive Data
5
SLT_TX
Transmit Data
6,7,8
Not used