5.1.3.1
Door Phone Box Installation
The Door Phone Box can be wall mounted in a protected environment; the DPB is not intended for exterior
application. To wall mount the LDP-DPB,
1)
Locate the mounting position for the Door Phone Box,
2)
Mark position for two (2) screws
3)
Drill holes for two (2) plastic anchors
4)
Insert screws and tighten leaving about ¼ inch exposed.
5)
Align the screw holes in the back of the LDP-DPB with the screws and slide down to lock in place.
It may be necessary to remove the box and loosen or tighten the screws for a secure fit.
5.1.3.2
Door Phone Box Wiring
The Door Phone Box is wired using screw terminals in the box. The terminals are wired to any available DKT
port except for the first DKT port.
1)
Refer to Figure 5.1.3.2-1 and the pin-out chart below,
2)
Loosen the screw holding the Door Phone Box cover.
3)
Loosen the two (2) screw terminals.
4)
Using a UTP cable terminated on one end with an RJ11, strip approximately ¼ inch of insulation
from the center pair at the un-terminated end of the wire.
5)
Insert the DKT Tip in one terminal and the DKT Ring.
6)
Tighten the screws to connect and securely fasten the wires.
7)
Plug the terminated end of the wire into a standard wall outlet with an RJ11.
8)
Wire the wall outlet 1st pair to the DTIB or DSIU termination point using UTP cable.
Figure 5.1.3.2-1 Door Phone Box Wiring
Table 5.1.3.2-1 LDP-DPB Pin-out Chart
Line Cord
CONNECTOR
PIN
SIGNAL NAME
RJ11
1,2
Not used
3
Ring
4
Tip
5,6
Not used