![iPECS eMG800 Hardware Description & Installation Manual Download Page 58](http://html1.mh-extra.com/html/ipecs/emg800/emg800_hardware-description-and-installation-manual_2088622058.webp)
iPECS eMG800
Hardware Description and Installation Manual
Issue 1.8
50
LD11
The status of 11
th
port or 23
rd
port
ON (Blue) : 11
th
port Use
ON (Yellow Green) : 23
rd
port in use
ON (Blush white) : 11
th
and 23
rd
port in use
OFF: Idle
LD12
The status of 12
th
port or 24
th
port
ON (Blue) : 12
th
port in use
ON (Yellow Green) : 24
th
port in use
ON (Blush white) : 12
th
and 24
th
port in use
OFF: Idle
LD13
ACT, Activation or Normal
Operating
Blink (Blue Color)
LD14
In use
ON: Ch. Use,
OFF: All channels Idle
4.4.2.2
SLIBC Installation
The SLIB has no switches or connectors that are field useable. The SLIB can be installed in any universal slot
of any KSU; the 1st slot of the BKSU is for the MPB only.
1)
Assure Power is OFF
2)
Slide the SLIBC in the guide rails of the desired slot.
3)
Tighten thumbscrews to hold the board firmly in place.
4.4.2.3
SLIBC Wiring
Each SLT port is terminated to a pair in the RJ21 connector. SLT 1 is terminated at pair 1, SLT 2 is terminated
on pair 2, etc. to the number of ports (12 or 24) on the SLIBC.
Refer to the pin-out chart below,
Wire each SLT pair on the RJ21 connector to the SLT termination point using UTP cable. The
maximum total wire length is 7500M/24Kft of 22 AWG wire or 5000M/16Kft of 24 AWG wire. For
information on wiring the SLT, refer to section 5.1.2.2.
Tag or number wiring for maintenance.
Table 4.4.2.1-2 SLIBC Pin-Out Chart
CONNECTOR
PIN(VT)
PIN(VR)
COLOR CODE
SLIB PORT
RJ21
1
26
1
2
27
2
3
28
3
4
29
4
5
30
5
6
31
6
7
32
7
8
33
8
9
34
9
10
35
10
11
36
11