10. CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER
10.6 Device Range that Can Be Set
10 - 15
9
CONN
E
C
TION
T
O
S
H
ARP PLC
10
C
O
NN
ECTI
ON
T
O
SHI
N
KO
TECHN
OS IN
DIC
ATI
NG
C
O
NT
ROLLE
R
11
CONNECTION T
O
CH
INO
CONTROLLE
R
12
CONNECTION T
O
T
O
SHI
B
A
PL
C
13
CONNECTION T
O
T
O
SH
IB
A M
A
C
H
IN
E
PLC
14
CONNECTION T
O
P
A
NA
SONIC S
E
R
V
O
A
M
PL
IF
IE
R
15
CONNE
CTION T
O
PA
NA
SONIC
INDUSTRI
AL
DE
VI
CES
SU
NX
PLC
10.6 Device Range that Can Be Set
The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
*1
The device name is displayed as follows when the memory
number (0 to 7) is set.
*2
The following shows the relation between station numbers of
the indicating controller and the GOT data register.
10.6.1 SHINKO indicating controller
(Shinko Technos Controller)
*1
As bit specification of a word device is performed after the
GOT reads the value, do not change the value with the
indicating controller during this period.
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
Memory
No.
*1
Set the memory number (None, 0 to 7) of the
device to be monitored.
Information
Displays the device type and setting range which are
selected in [Device].
Network
Set the monitor target of the set device.
All
Select this item when writing data to all the
indicating controllers connected.
During monitoring, the indicating controller which
is set for [Host Address] of the communication
detail setting is monitored.
(When writing the data in numerical input, the
data is written to all connected indicating
controllers during input, and the indicating
controller that is set for [Host Address] is
monitored during other than input (displaying).)
Station
No.
Select this item when monitoring the indicating
controller of the specified station No.
After selecting, set the station No. of the
indicating controller in the following range.
0 to 94:
To monitor the indicating controller
of the specified station No.
95:
Same as the setting of [All].
100 to 115:
To specify the station No. of the
indicating controller to be
monitored by the value of GOT
data register (GD).
*2
Memory No.
Displayed device name
None
Device Number
0
M0/Device Number
1
M1/Device Number
2
M2/Device Number
3
M3/Device Number
4
M4/Device Number
5
M5/Device Number
6
M6/Device Number
7
M7/Device Number
Station
No.
GOT data register (GD)
Setting range
100
GD10
0 to 94
(If setting a value
outside the range
above, a device range
error occurs.)
101
GD11
:
:
114
GD24
115
GD25
Device name
Setting range
Device No.
representation
B
it device
Word device bit
*1
Specified bit of the following
word devices
-
W
o
rd device
Data item (..)
..0001 to ..7901
Hexadecimal
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......