2 - 22
2. CONNECTION TO IAI ROBOT CONTROLLER
2.5 Robot Controller Side Setting
2.5.2
Connecting to SSEL, ASEL,
PSEL
Parameter setting
Enter the following parameters using peripheral
software. When setting parameters, set the mode
switch of the controller to "MANU".
*1
Indicates only the transmission that can be specified on the
GOT side.
Specify the transmission speed to match the baud rate of the
GOT.
*2
Set it only when a wait time is required before the response
and transmission to the GOT request. Normally, the
communication is available using default values.
Mode switch
Set the mode switch to "AUTO" and connect the GOT
to the following teaching connector.
2.5.3
Connecting to PCON, ACON,
SCON
Axis number setting, Mode select
For controllers without the following switches, set from
the setting tool (PC software).
Transmission speed setting
Set the transmission speed from the setting tool (PC
software).
*1
Indicates only the transmission speeds that can be set on
the GOT side.
Set the same transmission speed of the GOT.
Parameter
Parameter Name
Set Value
I/O parameter 90
Usage of SIO channel 0
opened to user
2: IAI protocol B
(fixed)
I/O parameter 91
Station code of SIO channel 0
opened to user
0 to 255
I/O parameter 92
*1
Baud rate type of SIO
channel 0 opened to user
0: 9600bps
1: 19200bps
2: 38400bps
3: 57600bps
5: 115200bps
I/O parameter 93
Data length of SIO channel 0
opened to user
7bit, 8bit
I/O parameter 94
Stop bit length of SIO
channel 0 opened to user
1bit, 2bit
I/O parameter 95
Parity type of SIO channel 0
opened to user
0: None
1: Odd
2: Even
I/O parameter 97
*2
IAI-protocol minimum
response delay for SIO
channel 0
opened to user
0 to 999(ms)
Other parameter
46
Other setting bit pattern 1
bit0 to 3 = 1
(fixed)
Mode switch
Teaching
connector
Switch
Setting details
Axis number setting
rotary switch
0 to 15
Mode selector switch
<Only the monitor>
AUTO
<monitor, data change>
MANU
Item
Range
SIO transmission
speed
*1
9600/19200/38400/57600/115200bps
Default: 38400bps
MANU
AUTO
Mode
selector switch
Axis number setting
rotary switch
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......