4. CONNECTION TO OMRON PLC
4.3 Ethernet Connection
4 - 37
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
C
O
NNECTION T
O
IAI
ROBO
T
CO
N
T
RO
L
L
E
R
3
CONNECTION T
O
AZBI
L C
O
NTR
O
L
EQUI
PMENT
4
CONNECTION T
O
OMRON PLC
5
CONNECTI
O
N T
O
OMRO
N TEMPERA
TURE
CONTROL
LE
R
6
CONNECTION T
O
KE
YENCE PL
C
7
CONNE
C
T
ION T
O
KO
YO
EI
PLC
8
CONN
E
CT
ION T
O
JT
EK
T PL
C
*1
Click the [Setting] button and perform the setting in the [GOT
IP Address Setting] screen.
*2
By setting of the OMRON PLC, set the same [GOT
Communication Port No.] setting as that of [FINS UDP Port ]
of CX-Programmer.
*3
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.
(2) GT15, GT12
*1
By setting of the OMRON PLC, set the same [GOT
Communication Port No.] setting as that of [FINS UDP Port ]
of CX-Programmer.
*2
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.
Item
Description
Range
GOT NET No.
Set the network No. of the
GOT.
(Default: 1)
1 to 127
GOT PLC No.
*2
Set the station No. of the GOT.
(Default: 1)
1 to 254
GOT IP Address
Set the IP address of the GOT.
(Default: 192.168.0.18)
0.0.0.0 to
255.255.255.
255
Subnet Mask
Set the subnet mask for the
sub network. (Only for
connection via router) If the
sub network is not used, the
default value is set.
(Default: 255.255.255.0)
0.0.0.0 to
255.255.255.
255
Default Gateway
Set the router address of the
default gateway where the
GOT is connected. (Only for
connection via router)
(Default: 0.0.0.0)
0.0.0.0 to
255.255.255.
255
Ethernet Download
Port No.
Set the GOT port No. for
Ethernet download.
(Default: 5014)
1024 to 5010,
5014 to
65534
(Except for
5011, 5012,
5013 and
49153)
GOT Communication
Port No.
*1
Set the GOT port No. for the
connection with the Ethernet
module.
(Default: 5018)
1024 to 5010,
5014 to
65534
(Except for
5011, 5012,
5013 and
49153)
Retry
Set the number of retries to be
performed when a
communication timeout
occurs.When receiving no
response after retries, the
communication times out.
(Default: 3times)
0 to 5times
Startup Time
Specify the time period from
the GOT startup until GOT
starts the communication with
the PLC CPU. (Default: 3sec)
3 to 255sec
Timeout Time
Set the time period for a
communication to time out.
(Default: 3sec)
3 to 90sec
Delay Time
Set the delay time for reducing
the load of the network/
destination PLC. (Default:
0ms)
0 to 10000
( 10ms)
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......