7 - 18
7. CONNECTION TO KOYO EI PLC
7.3 Connection Diagram
RS422 connection diagram 9)
*1
Connect FG grounding to the appropriate part of a cable
shield line.
*2
Connect a terminating resistor (approximately 150 ) to the
PLC at a terminal station.
RS422 connection diagram 10)
*1
Connect FG grounding to the appropriate part of a cable
shield line.
*2
Connect a terminating resistor (approximately 150 ) to the
PLC at a terminal station.
RS422 connection diagram 11)
*1
Connect FG grounding to the appropriate part of a cable
shield line.
*2
Connect a terminating resistor (approximately 150 ) to the
PLC at a terminal station.
RS422 connection diagram 12)
*1
Connect FG grounding to the appropriate part of a cable
shield line.
*2
Connect a terminating resistor (approximately 100 to 500 )
to the PLC to be a terminal.
GOT side
RDA
RDB
SDA
SDB
RSA
RSB
CSA
CSB
SG
FG
2
7
1
6
3
8
4
9
5
-
14
16
9
10
1 to 6
8
12
13
7
15
17
18
19
20 to 22
23
11
24, 25
+TXD
-TXD
+RXD
-RXD
-
-
-
-
SG
-
-
-RTS
+RTS
-
-CTS
+CTS
-
KOYO EI PLC side
*1
*2
GOT side
RDA
RDB
SDA
SDB
RSA
RSB
CSA
CSB
SG
FG
2
7
1
6
3
8
4
9
5
-
12
13
24
25
1 to 6
8 to 11
14 to 23
-
7
+TXD3
-TXD3
+RXD3
-RXD3
-
-
-
-
SG
KOYO EI PLC side
*1
*2
GOT side
RDA
RDB
SDA
SDB
RSA
RSB
CSA
CSB
SG
FG
2
7
1
6
3
8
4
9
5
-
14
15
17
16
1to 6
8
9
18 to 21
7
10
11
12
13
22
23
24
25
+TXD
-TXD
+RXD
-RXD
-
+RTS
-RTS
-
LG
+RTS
-RTS
+CTS
-CTS
+TXD
-TXD
-RXD
+RXD
KOYO EI PLC side
*1
*2
GOT side
RDA
RDB
SDA
SDB
RSA
RSB
CSA
CSB
SG
FG
2
7
1
6
3
8
4
9
5
-
9
10
13
6
1
2 to 5
8
7
11
12
14
15
+TXD
-TXD
+RXD
-RXD
5V
-
0V
0V
+RTS
-RTS
+CTS
-CTS
KOYO EI PLC side
*1
*2
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......