7. CONNECTION TO KOYO EI PLC
7.6 Device Range that Can Be Set
7 - 27
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
C
O
NNECTION T
O
IAI
ROBO
T
CO
N
T
RO
L
L
E
R
3
CONNECTION T
O
AZBI
L C
O
NTR
O
L
EQUI
PMENT
4
CONNECTION T
O
OMRON PLC
5
CONNECTI
O
N T
O
OMRO
N TEMPERA
TURE
CONTROL
LE
R
6
CONNECTION T
O
KE
YENCE PL
C
7
CONNE
C
T
ION T
O
KO
YO
EI
PLC
8
CONN
E
CT
ION T
O
JT
EK
T PL
C
7.6 Device Range that Can Be Set
The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
7.6.1
KOYO EI PLC
(KOYO KOSTAC/DL)
*1
Read-only device for KOSTAC SU series
*2
The GOT cannot write data to R7377 for the SU-5M and SU-
6M.
*3
For Direct Logic 05 series and Direct Logic 06 series,
devices from R1200 to R1377 are used as V-memory 2.
*4
The GOT cannot write data to devices from R7766 to R7774
(calendar area).
*5
The device names differ according to the series.
The following shows the device names for each series.
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
Information
Displays the device type and setting range which are
selected in [Device].
Network
Set the monitor target of the set device.
Station
No.
Select this item when monitoring the PLC of the
specified station No.
Device name
Setting range
Device
No.
represent
ation
Bit
d
e
vi
ce
Input (I)
*5
I0 to I1777
Octal
Output (Q)
*5
Q0 to Q1777
Link relay (GI)
GI0 to GI3777
Link output (GQ)
GQ0 to GQ3777
Internal relay (M)
M0 to M3777
Stage (S)
S0 to S1777
Timer (T)
T0 to T377
Counter (C)
C0 to C377
Special relay (SP)
*1
SP0 to SP777
W
o
rd
device
Timer (current value) (R)
R0 to R377
Preparatory register (R)
*5
R400 to R677
Special register 1 (R)
*1*5
R700 to R777
Timer (current value) (R)
*3
R1000 to R1377
Data register 1 (R)
*2*5
R1400 to R7377
Special register 2 (R)
*1*4*5
R7400 to R7777
Data register 2 (R)
*5
R10000 to R36777
Special register 3 (R)
*1*5
R37000 to R37777
Link relay (R)
R40000 to R40177
Link output (R)
R40200 to R40377
Input (R)
R40400 to R40477
Output (R)
R40500 to R40577
Internal relay (R)
R40600 to R40777
Stage (R)
R41000 to R41077
Timer (R)
R41100 to R41117
Counter (R)
R41140 to R41157
Special relay (R)
R41200 to R41237
KOSTAC SU
PZ
Direct Logic 05
Direct Logic 06
Direct Logic 205
Input
Input relay
Input
Output
Output relay
Output
Preparatory
register
V-memory 1
Data register 1
Special register 1
System parameter 1
System parameter 1
Data register 1
V-memory 2
Data register 2
Special register 2
System parameter 2
System parameter 2
Data register 2
V-memory 3
Data register 3
Special register 3
System parameter 4
System parameter 4
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......