background image

OIL DISPENSING SYSTEM AIR OPERATED

MODEL NO: 

AK4562

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 
and properly maintained, give you years of trouble free performance.

1.

SAFETY

‰

WARNING!

 Ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this 

equipment.

9

  Familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to this product.

9

  

Maintain the pump station in good condition (use an authorised service agent).

9

Replace or repair damaged parts. Use genuine parts only. Non authorised parts will invalidate the warranty.

9

Use only to pump lubricants up to SAE 150 viscosity. 

9

  

Ensure safety eye protection, oil resistant gloves and protective clothing are worn when using this product.

9

Keep the work area clean, uncluttered and ensure there is adequate lighting.

9

   Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.

9

Keep children and unauthorised persons away from the working area.

9

   After use, drain any fluids from the equipment before storage. 

9

  

Dispose of waste liquids in accordance with local authority regulations.

9

  

Disconnect air pressure from equipment when not in use.

8

DO NOT

exceed the maximum air pressure of 115psi.

8

DO NOT

point the nozzle at people or animals.

8

DO NOT

use the equipment near open flames.

8

  

DO NOT

smoke whilst using this equipment.

8

DO NOT

use to extract corrosive fluids.

8

DO NOT

 dismantle, tamper with or adapt the pump for any purpose other than for which it is designed.

8

DO NOT

use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.

8

DO NOT

leave the trolley on a slope, or traverse slopes, which may cause the unit to topple. 

9

The unit must be stored on a level surface.

9

Keep the pump clean and store in a safe dry, childproof location. 

‰

WARNING! DO NOT

allow uncontrolled discharge of fluids thus polluting the environment. All liquids must be disposed of according to  

authority regulations.

2.

i

INTRODUCTION

 Mobile oil dispensing unit with air operated 3:1 double acting pump for barrels or 

tanks with 2”BSP fittings. Pump is supplied with air management system 
connected to a 940mm rigid suction probe with non-return valve. Features 
10mtr retractable hose reel and digital oil meter Model No. AK4565D. Suitable 
for use with engine, hydraulic, synthetic, gear, and transmission oils up to SAE150.

3.

i

SPECIFICATION

Model No: ...............................................................AK4562D
Maximum Air Pressure: ................................................115psi
Maximum Flow Rate: ............................................... 12ltr/min
Maximum Output Pressure: ........................................ 350psi
Maximum Trolley Capacity: .......................................... 220kg
Maximum Viscosity: .................................................. SAE150
Nett Weight: ................................................................72.6Kg
O

utlet Size:

...............................................................1/2”BSP

Pump Ratio: ...................................................................... 3:1
Recommended Air Pressure: ........................................ 70psi

Digital Hose End Meter

Model ......................................................................AK4565D
Accuracy: ..................................................................+/- 0.5%
Inlet: ..........................................................................1/2”BSP
Battery: ......................................... Lithium CR2 3V 1400mAH

AK4562D  Issue 3 (H, 5, F)  24/09/18

Original Language Version

© Jack Sealey Limited

Refer to 

instruction

manual

Wear protective 

gloves

Wear eye 

protection

Wear protective 

clothing

Wear safety 

footwear

Summary of Contents for AK4562

Page 1: ...nnect air pressure from equipment when not in use 8 DO NOT exceed the maximum air pressure of 115psi 8 DO NOT point the nozzle at people or animals 8 DO NOT use the equipment near open flames 8 DO NOT smoke whilst using this equipment 8 DO NOT use to extract corrosive fluids 8 DO NOT dismantle tamper with or adapt the pump for any purpose other than for which it is designed 8 DO NOT use the unit i...

Page 2: ...the base plate and secure using four bolts washers and nuts not shown in fig 1 4 2 PUMP AND AIR REGULATOR LUBRICATOR ASSEMBLY 4 2 1 Apply a small amount of liquid thread sealant onto the threads of the air inlet of the pump and attach the air regulator lubricator fig 2 WARNING DO NOT allow thread sealant to enter the pump 4 2 2 Attach the outlet pipe to the male outlet thread on the pump and attac...

Page 3: ...urrent total resets to 0 00 5 2 5 To display correction factor and Total fig 8 Hold MOVE and RESET for 3 seconds Value 1 4000 is correction factor 1234567 overall total 5 2 6 To change Units fig 9 Hold MOVE and RESET for several seconds Area 2 in fig 5 shows units Press RESET to change units Press and hold MOVE to confirm choice 5 3 DETERMINING THE CORRECTION FACTOR 5 3 1 Dispense at least 1 litre...

Page 4: ...es sealey co uk www sealey co uk ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers a...

Reviews: