14 - 8
14. CONNECTION TO PANASONIC SERVO AMPLIFIER
14.3 Connection Diagram
Precautions when preparing a cable
(1) Cable length
The length of the RS-485 cable must be 1m or less.
(2) GOT side connector
For the GOT side connector, refer to the following.
1.4.1 GOT connector specifications
(3) PANASONIC servo amplifier side connector
Use the connector compatible with the PANASONIC
servo amplifier.
For details, refer to the user's manual of the
PANASONIC servo amplifier.
Connecting terminating resistors
(1) GOT side
When connecting a PANASONIC servo amplifier to the
GOT, a terminating resistor must be connected to the
GOT.
(a) For GT16, GT15, GT12
Set the terminating resistor setting switch of the
GOT main unit to "Disable".
(b) For GT14, GT11
Set the terminating resistor selector to "110 ".
For details of terminating resistor settings, refer to
the following.
1.4.3 Terminating resistors of GOT
14.3.3 RS-232/RS-485 cable
Connection diagram
RS232/485 connection diagram 1)
*1
GT16/15:CD, GT11:NC
Precautions when preparing a cable
(1) Cable length
• The length of the cable between GOT and MINAS
must be 2m or less.
• The length of the cable between MINAS and MINAS
must be 1m or less.
(2) GOT side connector
For the GOT side connector, refer to the following.
1.4.1 GOT connector specifications
(3) PANASONIC servo amplifier side connector
Use the connector compatible with the PANASONIC
servo amplifier.
For details, refer to the user's manual of the
PANASONIC servo amplifier.
CD/NC
*1
RD(RXD)
SD(TXD)
ER(DTR)
SG
DR(DSR)
RS(RTS)
CS(CTS)
-
1
2
3
4
5
6
7
8
9
RS485-
RS485+
RS485-
RS485+
FG
GND
NC
TXD
RXD
1
2
3
4
5
6
7
8
Shell
RS485-
RS485+
RS485-
RS485+
FG
GND
NC
TXD
RXD
1
2
3
4
5
6
7
8
Shell
RS485-
RS485+
RS485-
RS485+
FG
GND
NC
TXD
RXD
1
2
3
4
5
6
7
8
Shell
GOT side
PANASONIC servo amplifier side
PANASONIC servo amplifier side
PANASONIC servo amplifier side
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......